On 15/05/17 02:54, Guenter Roeck wrote: > On 05/10/2017 08:45 PM, Chris Packham wrote: >> By default adt7475 will stop the fans (pwm duty cycle 0%) when the >> temperature drops past Tmin - hysteresis. Some systems want to keep the >> fans moving even when the temperature drops so add new sysfs attributes >> that configure the enhanced acoustics min 1-3 which allows the fans to >> run at the minimum configure pwm duty cycle. >> >> Signed-off-by: Chris Packham <chris.packham@xxxxxxxxxxxxxxxxxxx> >> --- >> >> Changes in v2: >> - use pwmN_stall_dis as the attribute name. I think this describes the purpose >> pretty well. I went with a new attribute instead of overloading > > Almost agree. Can we use pwmN_stall_disable ? > Sold. I'll send a v4 of this patch with the name changed. > Thanks, > Guenter > > >> pwmN_auto_point1_pwm so this doesn't affect existing users. >> Changes in v3: >> - Fix grammar. >> - change enh_acou to enh_acoustics -- To unsubscribe from this list: send the line "unsubscribe linux-doc" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html