Re: [PATCH v3 0/4] thermal: re-calculate k_po/k_pu when update sustainable power

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Wed, Jan 06, 2016 at 04:53:44PM +0800, Leo Yan wrote:
> k_po/k_pu are two proportional term constants and essentially they have
> fixed ratio compared with sustainable power. In current implementation,
> k_po and k_pu are absolute value after calculation and cannot represent
> the ratio relationship with sustainable power; as a result, when change
> sustainable power we cannot smoothly change proportional term constant.

In v2 Daniel said that the use case was made up.  Can you elaborate on
why we need this?

> So this patch series introduces k_po_ratio and k_pu_ratio, which
> represent the ratio value compared against sustainable power. Also add
> sys file system nodes for them for easily update them from userspace and
> update a bit in documentation.

Actually, it makes it harder to update from userspace.  Now userspace
can't set a k_po/k_pu any more, and it's forced to set them as ratios
of sustainable power. I'd rather not do this unless there is a good
reason for it.

Cheers,
Javi
--
To unsubscribe from this list: send the line "unsubscribe linux-doc" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html