On Tue, Feb 25, 2025 at 05:47:52PM -0800, Jakub Kicinski wrote: > On Tue, 25 Feb 2025 10:25:58 +0100 Kory Maincent wrote: > > On Mon, 24 Feb 2025 13:45:22 -0800 > > Jakub Kicinski <kuba@xxxxxxxxxx> wrote: > > > > > > No they can't for now. Even different PSE power domains within the same PSE > > > > controller. I will make it explicit. > > > > > > Sounds like the property is placed at the wrong level of the hierarchy, > > > then. > > > > When a PSE controller appears to be able to support mixed budget strategy and > > could switch between them it will be better to have it set at the PSE power > > domain level. As the budget is per PSE power domain, its strategy should also > > be per PSE power domain. > > For now, it is simply not configurable and can't be mixed. It is hard-coded by > > the PSE driver. > > Yes, but uAPI is forever. We will have to live with those domain > attributes duplicated on each port. Presumably these port attributes > will never support a SET operation, since the set should be towards > the domain? The uAPI does not inspire confidence. If we need more > drivers to define a common API maybe a local sysfs API in the driver > will do? I tend to disagree here. The evaluation/allocation methods should be per port. At this step, we support only "hardware"(firmware)-based methods: 1. Static – Plain hardware classification-based power allocation per port. 2. Dynamic – Hardware classification with constant measurement for optimization. For some devices, the dynamic method may not work reliably enough, so we will need to switch to a fixed allocation method, which is currently not implemented but will be set via user space. This should be configurable per port. At some point, we will need to introduce LLDP-based allocation from user space. This will be managed by a daemon. For testing, here’s an example of how LLDP-based power negotiation can be analyzed: https://telecomtest.com.au/wp-content/uploads/2016/12/PDA-LLDP-Powered-Device-LLDP-Analyzer.pdf -- Pengutronix e.K. | | Steuerwalder Str. 21 | http://www.pengutronix.de/ | 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |