Switching between local and total memory bandwidth events as the input to the mba_sc feedback loop would be cumbersome and take effect slowly in the current implementation as the bandwidth is only known after two consecutive readings of the same event. Compute the bandwidth for all supported events. This doesn't add significant overhead and will make changing which event is used simple. Suggested-by: Reinette Chatre <reinette.chatre@xxxxxxxxx> Signed-off-by: Tony Luck <tony.luck@xxxxxxxxx> --- arch/x86/kernel/cpu/resctrl/monitor.c | 72 ++++++++++++--------------- 1 file changed, 33 insertions(+), 39 deletions(-) diff --git a/arch/x86/kernel/cpu/resctrl/monitor.c b/arch/x86/kernel/cpu/resctrl/monitor.c index 6fe2e6ab8dd4..4ca38bc9dd96 100644 --- a/arch/x86/kernel/cpu/resctrl/monitor.c +++ b/arch/x86/kernel/cpu/resctrl/monitor.c @@ -663,9 +663,12 @@ static int __mon_event_count(u32 closid, u32 rmid, struct rmid_read *rr) */ static void mbm_bw_count(u32 closid, u32 rmid, struct rmid_read *rr) { - u32 idx = resctrl_arch_rmid_idx_encode(closid, rmid); - struct mbm_state *m = &rr->d->mbm_local[idx]; u64 cur_bw, bytes, cur_bytes; + struct mbm_state *m; + + m = get_mbm_state(rr->d, closid, rmid, rr->evtid); + if (WARN_ON_ONCE(!m)) + return; cur_bytes = rr->val; bytes = cur_bytes - m->prev_bw_bytes; @@ -815,54 +818,45 @@ static void update_mba_bw(struct rdtgroup *rgrp, struct rdt_mon_domain *dom_mbm) resctrl_arch_update_one(r_mba, dom_mba, closid, CDP_NONE, new_msr_val); } -static void mbm_update(struct rdt_resource *r, struct rdt_mon_domain *d, - u32 closid, u32 rmid) +static void mbm_update_one_event(struct rdt_resource *r, struct rdt_mon_domain *d, + u32 closid, u32 rmid, enum resctrl_event_id evtid) { struct rmid_read rr = {0}; rr.r = r; rr.d = d; + rr.evtid = evtid; + rr.arch_mon_ctx = resctrl_arch_mon_ctx_alloc(rr.r, rr.evtid); + if (IS_ERR(rr.arch_mon_ctx)) { + pr_warn_ratelimited("Failed to allocate monitor context: %ld", + PTR_ERR(rr.arch_mon_ctx)); + return; + } + + __mon_event_count(closid, rmid, &rr); /* - * This is protected from concurrent reads from user - * as both the user and we hold the global mutex. + * If the software controller is enabled, compute the + * bandwidth for this event id. */ - if (is_mbm_total_enabled()) { - rr.evtid = QOS_L3_MBM_TOTAL_EVENT_ID; - rr.val = 0; - rr.arch_mon_ctx = resctrl_arch_mon_ctx_alloc(rr.r, rr.evtid); - if (IS_ERR(rr.arch_mon_ctx)) { - pr_warn_ratelimited("Failed to allocate monitor context: %ld", - PTR_ERR(rr.arch_mon_ctx)); - return; - } + if (is_mba_sc(NULL)) + mbm_bw_count(closid, rmid, &rr); - __mon_event_count(closid, rmid, &rr); - - resctrl_arch_mon_ctx_free(rr.r, rr.evtid, rr.arch_mon_ctx); - } - if (is_mbm_local_enabled()) { - rr.evtid = QOS_L3_MBM_LOCAL_EVENT_ID; - rr.val = 0; - rr.arch_mon_ctx = resctrl_arch_mon_ctx_alloc(rr.r, rr.evtid); - if (IS_ERR(rr.arch_mon_ctx)) { - pr_warn_ratelimited("Failed to allocate monitor context: %ld", - PTR_ERR(rr.arch_mon_ctx)); - return; - } - - __mon_event_count(closid, rmid, &rr); + resctrl_arch_mon_ctx_free(rr.r, rr.evtid, rr.arch_mon_ctx); +} - /* - * Call the MBA software controller only for the - * control groups and when user has enabled - * the software controller explicitly. - */ - if (is_mba_sc(NULL)) - mbm_bw_count(closid, rmid, &rr); +static void mbm_update(struct rdt_resource *r, struct rdt_mon_domain *d, + u32 closid, u32 rmid) +{ + /* + * This is protected from concurrent reads from user as both + * the user and overflow handler hold the global mutex. + */ + if (is_mbm_total_enabled()) + mbm_update_one_event(r, d, closid, rmid, QOS_L3_MBM_TOTAL_EVENT_ID); - resctrl_arch_mon_ctx_free(rr.r, rr.evtid, rr.arch_mon_ctx); - } + if (is_mbm_local_enabled()) + mbm_update_one_event(r, d, closid, rmid, QOS_L3_MBM_LOCAL_EVENT_ID); } /* -- 2.47.0