From: Kory Maincent (Dent Project) <kory.maincent@xxxxxxxxxxx> The PI of_node was not assigned in the regulator_config structure, leading to failures in resolving the correct supply when different power supplies are assigned to multiple PIs of a PSE controller. This fix ensures that the of_node is properly set in the regulator_config, allowing accurate supply resolution for each PI. Signed-off-by: Kory Maincent <kory.maincent@xxxxxxxxxxx> --- Changes in v3: - New patch --- drivers/net/pse-pd/pse_core.c | 1 + 1 file changed, 1 insertion(+) diff --git a/drivers/net/pse-pd/pse_core.c b/drivers/net/pse-pd/pse_core.c index 8b5a9e7fd9c5..d4cf5523194d 100644 --- a/drivers/net/pse-pd/pse_core.c +++ b/drivers/net/pse-pd/pse_core.c @@ -419,6 +419,7 @@ devm_pse_pi_regulator_register(struct pse_controller_dev *pcdev, rconfig.dev = pcdev->dev; rconfig.driver_data = pcdev; rconfig.init_data = rinit_data; + rconfig.of_node = pcdev->pi[id].np; rdev = devm_regulator_register(pcdev->dev, rdesc, &rconfig); if (IS_ERR(rdev)) { -- 2.34.1