[PATCH RFC net-next v3 18/27] net: pse-pd: Fix missing PI of_node description

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



From: Kory Maincent (Dent Project) <kory.maincent@xxxxxxxxxxx>

The PI of_node was not assigned in the regulator_config structure, leading
to failures in resolving the correct supply when different power supplies
are assigned to multiple PIs of a PSE controller. This fix ensures that the
of_node is properly set in the regulator_config, allowing accurate supply
resolution for each PI.

Signed-off-by: Kory Maincent <kory.maincent@xxxxxxxxxxx>
---

Changes in v3:
- New patch
---
 drivers/net/pse-pd/pse_core.c | 1 +
 1 file changed, 1 insertion(+)

diff --git a/drivers/net/pse-pd/pse_core.c b/drivers/net/pse-pd/pse_core.c
index 8b5a9e7fd9c5..d4cf5523194d 100644
--- a/drivers/net/pse-pd/pse_core.c
+++ b/drivers/net/pse-pd/pse_core.c
@@ -419,6 +419,7 @@ devm_pse_pi_regulator_register(struct pse_controller_dev *pcdev,
 	rconfig.dev = pcdev->dev;
 	rconfig.driver_data = pcdev;
 	rconfig.init_data = rinit_data;
+	rconfig.of_node = pcdev->pi[id].np;
 
 	rdev = devm_regulator_register(pcdev->dev, rdesc, &rconfig);
 	if (IS_ERR(rdev)) {

-- 
2.34.1