Hi Tony, On 11/9/2023 3:09 PM, Tony Luck wrote: > The same rdt_domain structure is used for both control and monitor > functions. But this results in wasted memory as some of the fields are > only used by control functions, while most are only used for monitor > functions. > > Split into separate rdt_ctrl_domain and rdt_mon_domain structures with > just the fields required for control and monitoring respectively. > > Similar split of the rdt_hw_domain structure into rdt_hw_ctrl_domain > and rdt_hw_mon_domain. > > Reviewed-by: Peter Newman <peternewman@xxxxxxxxxx> > Signed-off-by: Tony Luck <tony.luck@xxxxxxxxx> > --- Reviewed-by: Reinette Chatre <reinette.chatre@xxxxxxxxx> Reinette