Re: [PATCH v2 1/2] Documentation: fpga: dfl: add PCI Identification documentation

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 




On 3/2/22 4:35 PM, matthew.gerlach@xxxxxxxxxxxxxxx wrote:
From: Matthew Gerlach <matthew.gerlach@xxxxxxxxxxxxxxx>

Add documentation on identifying FPGA based PCI cards prompted
by discussion on the linux-fpga@xxxxxxxxxxxxxxx mailing list.

Signed-off-by: Matthew Gerlach <matthew.gerlach@xxxxxxxxxxxxxxx>
---
v2: Introduced in v2.
---
  Documentation/fpga/dfl.rst | 20 ++++++++++++++++++++
  1 file changed, 20 insertions(+)

diff --git a/Documentation/fpga/dfl.rst b/Documentation/fpga/dfl.rst
index ef9eec71f6f3..5fb2ca8e76d7 100644
--- a/Documentation/fpga/dfl.rst
+++ b/Documentation/fpga/dfl.rst
@@ -502,6 +502,26 @@ Developer only needs to provide a sub feature driver with matched feature id.
  FME Partial Reconfiguration Sub Feature driver (see drivers/fpga/dfl-fme-pr.c)
  could be a reference.
+PCI Device Identification
+================================
+Since FPGA based PCI cards can be reconfigured to a perform a completely
+new function at runtime, properly identifying such cards and binding the
+correct driver can be challenging. In many use cases, deployed FPGA based
+PCI cards are essentially static and the PCI Product ID and Vendor ID pair
+is sufficient to identify the card.  The DFL framework helps with the
+dynamic case of deployed FPGA cards changing at run time by providing
+more detailed information about card discoverable at runtime.
+
+At one level, the DFL on a PCI card describes the function of the card.
+However, the same DFL could be instantiated on different physical cards.
+Conversely, different DFLs could be instantiated on the same physical card.
+Practical management of a cloud containing a heterogeneous set of such cards
+requires a PCI level of card identification. While the PCI Product ID and
+Vendor ID may be sufficient to bind the dfl-pci driver, it is expected
+that FPGA PCI cards would advertise suitable Subsystem ID and Subsystem
+Vendor ID values. PCI Vital Product Data (VPD) can also be used for
+more granular information about the board.

This describes a bit more of the problem, it should describe it wrt ofs dev id. The introduction of the ofs dev should be explicitly called out as a generic pci id.

Why couldn't one of the old pci id's be reused ?

How will the subvendor/subid be enforced ?

Is the current security manager patchset smart enough to save the board from being bricked when a user doesn't look beyond the pci id ?

What happens if a board uses this device id but doesn't have a max10 to do the update ?