On Thu, May 03, 2012 at 05:57:49PM +0100, Mark Brown wrote: > On Thu, May 03, 2012 at 06:54:37PM +0200, Johan Hovold wrote: > > On Thu, May 03, 2012 at 04:24:07PM +0100, Mark Brown wrote: > > > > I'm not sure exactly which control that is? > > > That would be the output_lvled[n] (n = 1..5) attributes. For example, to > > have all five low-voltage sinks blink synchronously, you could assign 0 > > to all these five attributes, and set a timer trigger for the led device > > which has id 0. > > Sorry, I meant "what exactly does this do in hardware". >From the datasheet (page 14): "CONTROL BANK MAPPING Control of the LM3533's current sinks is not done directly, but through the programming of Control Banks. The current sinks are then assigned to the programmed Control Bank. This allows for a wide variety of current control possibilities where LEDs can be grouped and controlled via specific Control Banks (see Figure 3)." It is the control banks that has a brightness settings or can be programmed to blink, that is, they correspond to the logical LEDs and backlights. Assigning a current sink to a control bank corresponds, then, to setting, for example, output_lvled3 to (led) 1. [ Figure 3 on page 16 of the data sheet may be instructive. In the figure, BANK A and B corresponds to the two backlight devices, and BANK C through F corresponds to the four led devices. Note that there are more outputs (current sinks) than control banks. ] Thanks, Johan -- To unsubscribe from this list: send the line "unsubscribe linux-doc" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html