Re: [PATCH 0/2] hwrng: omap: Fix clock resource for Armada 7K/8K

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Wed, Feb 28, 2018 at 03:27:21PM +0100, Gregory CLEMENT wrote:
> Hi,
> 
> This short series fixes the way the clocks are used for the SafeXcel
> IP-76 controller embedded in the Marvell Armada 7K/8K SoCs. On these
> SoCs a second one is needed in order to clock the registers. It was
> not noticed until now because we relied on the bootloader and also
> because the clock driver was wrong.
> 
> Thanks to this fix, it would be possible to fix the clock driver
> without introducing a regression.
> 
> The first patch is just a small cleanup found when I wrote the main
> patch.
> 
> Gregory CLEMENT (2):
>   hwrng: omap - Remove useless test before clk_disable_unprepare
>   hwrng: omap - Fix clock resource by adding a register clock
> 
>  Documentation/devicetree/bindings/rng/omap_rng.txt |  7 ++++++-
>  drivers/char/hw_random/omap-rng.c                  | 22 ++++++++++++++++++----
>  2 files changed, 24 insertions(+), 5 deletions(-)

All applied.  Thanks.
-- 
Email: Herbert Xu <herbert@xxxxxxxxxxxxxxxxxxx>
Home Page: http://gondor.apana.org.au/~herbert/
PGP Key: http://gondor.apana.org.au/~herbert/pubkey.txt



[Index of Archives]     [Kernel]     [Gnu Classpath]     [Gnu Crypto]     [DM Crypt]     [Netfilter]     [Bugtraq]

  Powered by Linux