On 11/5/19 9:18 PM, Oliver Hartkopp wrote: > On 05/11/2019 19.49, Marc Kleine-Budde wrote: > > Case 1: >> I think we discussed that quite some time ago. Back in the days we >> decided that if the controller does support automatic restart via the >> "128 occurrences of 11 consecutive recessive bits" and restart-ms is > >> 0, we'll let the controller do the restart. > > Case 2: >> If restart-ms is 0, we'll shut down the controller and wait for a manual >> restart. > > Case 3: > When a CAN controller does not support automatic restart and enters > BUS_OFF state, we restart the CAN controller after restart-ms msecs. > > Right? ACK > Just to show the entire picture. Thanks, Marc -- Pengutronix e.K. | Marc Kleine-Budde | Industrial Linux Solutions | Phone: +49-231-2826-924 | Vertretung West/Dortmund | Fax: +49-5121-206917-5555 | Amtsgericht Hildesheim, HRA 2686 | http://www.pengutronix.de |
Attachment:
signature.asc
Description: OpenPGP digital signature