Hi Alain, > When an LE connection is requested and an RPA update is needed via > hci_connect_le_scan, the default scanning parameters are used rather > than the connect parameters. This leads to significant delays in the > connection establishment process when using lower duty cycle scanning > parameters. > > The patch simply looks at the pended connection list when trying to > determine which scanning parameters should be used. > > Before: > < HCI Command: LE Set Extended Scan Parameters (0x08|0x0041) plen 8 > #378 [hci0] 1659.247156 > Own address type: Public (0x00) > Filter policy: Ignore not in white list (0x01) > PHYs: 0x01 > Entry 0: LE 1M > Type: Passive (0x00) > Interval: 367.500 msec (0x024c) > Window: 37.500 msec (0x003c) > > After: > < HCI Command: LE Set Extended Scan Parameters (0x08|0x0041) plen 8 > #39 [hci0] 7.422109 > Own address type: Public (0x00) > Filter policy: Ignore not in white list (0x01) > PHYs: 0x01 > Entry 0: LE 1M > Type: Passive (0x00) > Interval: 60.000 msec (0x0060) > Window: 60.000 msec (0x0060) > > Reviewed-by: Abhishek Pandit-Subedi <abhishekpandit@xxxxxxxxxxxx> > Reviewed-by: Yu Liu <yudiliu@xxxxxxxxxx> > Signed-off-by: Alain Michaud <alainm@xxxxxxxxxxxx> please swap these around, the signed-off-by from the author should come first. > > --- > > Changes in v2: > - Fixing Yu's email tag > > net/bluetooth/hci_request.c | 24 ++++++++++++++++++++++++ > 1 file changed, 24 insertions(+) Patch has been applied to bluetooth-next tree. Regards Marcel