This change adds the definition for the load default parameter command. In particular, this command is used to load default parameters for various operations in the kernel. This mechanism is also expandable to future values that may be necessary. This will allow bluetoothd to load parameters from a conf file that may be customized for the specific requirements of each platforms. --- rebase against current master doc/mgmt-api.txt | 62 ++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 62 insertions(+) diff --git a/doc/mgmt-api.txt b/doc/mgmt-api.txt index 6ee01fed8..c6575e654 100644 --- a/doc/mgmt-api.txt +++ b/doc/mgmt-api.txt @@ -3223,6 +3223,68 @@ Set Experimental Feature Command Invalid Index +Load Default Controller Parameter Command +============================= + + Command Code: 0x004b + Controller Index: <controller id> + Command Parameters: Parameter_Count (2 Octets) + Parameter1 { + Parameter_Type (2 Octet) + Value_Length (1 Octet) + Value (0-255 Octets) + } + Parameter2 { } + ... + Return Parameters: + + This command is used to feed the kernel a list of default controller + parameters. + + Currently defined Parameter_Type values are: + + 0x0000 BR/EDR Page Scan Type + 0x0001 BR/EDR Page Scan Interval + 0x0002 BR/EDR Page Scan Window + 0x0003 BR/EDR Inquiry Scan Type + 0x0004 BR/EDR Inquiry Scan Interval + 0x0005 BR/EDR Inquiry Scan Window + 0x0006 BR/EDR Link Supervision Timeout + 0x0007 BR/EDR Page Timeout + 0x0008 BR/EDR Min Sniff Interval + 0x0009 BR/EDR Max Sniff Interval + 0x000a LE Advertisement Min Interval + 0x000b LE Advertisement Max Interval + 0x000c LE Multi Advertisement Rotation Interval + 0x000d LE Scanning Interval for auto connect + 0x000e LE Scanning Window for auto connect + 0x000f LE Scanning Interval for HID only + 0x0010 LE Scanning Window for HID only + 0x0012 LE Scanning Interval for wake scenarios + 0x0013 LE Scanning Window for wake scenarios + 0x0014 LE Scanning Interval for discovery + 0x0015 LE Scanning Window for discovery + 0x0016 LE Scanning Interval for adv monitoring + 0x0017 LE Scanning Window for adv monitoring + 0x0018 LE Scanning Interval for connect + 0x0019 LE Scanning Window for connect + 0x001a LE Min Connection Interval + 0x001b LE Max Connection Interval + 0x001c LE Connection Connection Latency + 0x001d LE Connection Supervision Timeout + + This command can be used when the controller is not powered and + all settings will be programmed once powered. Note that these only + control the default parameters. Higher level Apis may influence the + effective value used. + + This command generates a Command Complete event on success or + a Command Status event on failure. + + Possible errors: Invalid Parameters + Invalid Index + + Command Complete Event ====================== -- 2.26.2.761.g0e0b3e54be-goog