https://bugzilla.kernel.org/show_bug.cgi?id=60824 MasterCATZ (mastercatz@xxxxxxxxxxx) changed: What |Removed |Added ---------------------------------------------------------------------------- CC| |mastercatz@xxxxxxxxxxx --- Comment #46 from MasterCATZ (mastercatz@xxxxxxxxxxx) --- same boat have not used my Bluetooth dongle for years and need them again and can not get working Ubuntu 19 hciconfig hci0: Type: Primary Bus: USB BD Address: 00:11:67:55:8F:C3 ACL MTU: 672:3 SCO MTU: 48:1 DOWN RX bytes:918 acl:0 sco:0 events:32 errors:0 TX bytes:112 acl:0 sco:0 commands:32 errors:2 usb 5-1: USB disconnect, device number 2 [176552.338881] usb 5-1: new full-speed USB device number 4 using xhci_hcd [176552.494463] usb 5-1: config 1 interface 1 altsetting 0 endpoint 0x83 has wMaxPacketSize 0, skipping [176552.494466] usb 5-1: config 1 interface 1 altsetting 0 endpoint 0x3 has wMaxPacketSize 0, skipping [176552.503454] usb 5-1: New USB device found, idVendor=0a12, idProduct=0001, bcdDevice= 1.34 [176552.503456] usb 5-1: New USB device strings: Mfr=1, Product=2, SerialNumber=0 [176552.503458] usb 5-1: Product: USB demo board [176552.503458] usb 5-1: Manufacturer: Conwise Technology [176847.054212] usb 5-1: USB disconnect, device number 4 [176849.007636] usb 5-1: new full-speed USB device number 5 using xhci_hcd [176849.167625] usb 5-1: config 1 interface 1 altsetting 0 endpoint 0x83 has wMaxPacketSize 0, skipping [176849.167627] usb 5-1: config 1 interface 1 altsetting 0 endpoint 0x3 has wMaxPacketSize 0, skipping [176849.176617] usb 5-1: New USB device found, idVendor=0a12, idProduct=0001, bcdDevice= 1.34 [176849.176618] usb 5-1: New USB device strings: Mfr=1, Product=2, SerialNumber=0 [176849.176619] usb 5-1: Product: USB demo board [176849.176620] usb 5-1: Manufacturer: Conwise Technology [177010.700332] NET: Registered protocol family 38 [177027.690747] debugfs: File 'dut_mode' in directory 'hci0' already present! [177111.033769] usbcore: deregistering interface driver btusb [177115.941071] usbcore: registered new interface driver btusb sudo btmon Bluetooth monitor ver 5.50 = Note: Linux version 5.4.11-050411-generic (x86_64) 0.303554 = Note: Bluetooth subsystem version 2.22 0.303557 = New Index: 00:11:67:55:8F:C3 (Primary,USB,hci0) [hci0] 0.303588 @ MGMT Open: bluetoothd (privileged) version 1.14 {0x0001} 0.303589 @ MGMT Open: btmon (privileged) version 1.14 {0x0002} 0.303655 @ RAW Open: hciconfig (privileged) version 2.22 {0x0003} 17.071322 = Open Index: 00:11:67:55:8F:C3 [hci0] 17.186259 = Index Info: 00:11:67:55:8F:C3 (Cambridge Silicon Radio) [hci0] 17.186268 < HCI Command: Read Local Version Information (0x04|0x0001) plen 0 #1 [hci0] 17.186284 > HCI Event: Command Complete (0x0e) plen 12 > #2 [hci0] 17.189217 Read Local Version Information (0x04|0x0001) ncmd 1 Status: Success (0x00) HCI version: Bluetooth 2.0 (0x03) - Revision 500 (0x01f4) LMP version: Bluetooth 2.0 (0x03) - Subversion 500 (0x01f4) Manufacturer: Cambridge Silicon Radio (10) < HCI Command: Reset (0x03|0x0003) plen 0 #3 [hci0] 17.189246 > HCI Event: Command Complete (0x0e) plen 4 > #4 [hci0] 17.265218 Reset (0x03|0x0003) ncmd 1 Status: Success (0x00) < HCI Command: Read Local Supported Features (0x04|0x0003) plen 0 #5 [hci0] 17.265235 > HCI Event: Command Complete (0x0e) plen 12 > #6 [hci0] 17.267216 Read Local Supported Features (0x04|0x0003) ncmd 1 Status: Success (0x00) Features: 0xff 0x3e 0x05 0x30 0x18 0x18 0x00 0x00 3 slot packets 5 slot packets Encryption Slot offset Timing accuracy Role switch Hold mode Sniff mode Power control requests Channel quality driven data rate (CQDDR) SCO link HV2 packets HV3 packets CVSD synchronous data Power control Interlaced inquiry scan Interlaced page scan AFH capable slave AFH classification slave AFH capable master AFH classification master < HCI Command: Read Local Version Information (0x04|0x0001) plen 0 #7 [hci0] 17.267230 > HCI Event: Command Complete (0x0e) plen 12 > #8 [hci0] 17.270215 Read Local Version Information (0x04|0x0001) ncmd 1 Status: Success (0x00) HCI version: Bluetooth 2.0 (0x03) - Revision 500 (0x01f4) LMP version: Bluetooth 2.0 (0x03) - Subversion 500 (0x01f4) Manufacturer: Cambridge Silicon Radio (10) < HCI Command: Read BD ADDR (0x04|0x0009) plen 0 #9 [hci0] 17.270232 > HCI Event: Command Complete (0x0e) plen 10 > #10 [hci0] 17.276215 Read BD ADDR (0x04|0x0009) ncmd 1 Status: Success (0x00) Address: 00:11:67:55:8F:C3 (Integrated System Solution Corp.) < HCI Command: Read Buffer Size (0x04|0x0005) plen 0 #11 [hci0] 17.276270 > HCI Event: Command Complete (0x0e) plen 11 > #12 [hci0] 17.278218 Read Buffer Size (0x04|0x0005) ncmd 1 Status: Success (0x00) ACL MTU: 672 ACL max packet: 3 SCO MTU: 48 SCO max packet: 1 < HCI Command: Read Class of Device (0x03|0x0023) plen 0 #13 [hci0] 17.278240 > HCI Event: Command Complete (0x0e) plen 7 > #14 [hci0] 17.282211 Read Class of Device (0x03|0x0023) ncmd 1 Status: Success (0x00) Class: 0x120104 Major class: Computer (desktop, notebook, PDA, organizers) Minor class: Desktop workstation Networking (LAN, Ad hoc) Object Transfer (v-Inbox, v-Folder) < HCI Command: Read Local Name (0x03|0x0014) plen 0 #15 [hci0] 17.282282 > HCI Event: Command Complete (0x0e) plen 252 > #16 [hci0] 17.305215 Read Local Name (0x03|0x0014) ncmd 1 Status: Success (0x00) Name: POV-ION < HCI Command: Read Voice Setting (0x03|0x0025) plen 0 #17 [hci0] 17.305262 > HCI Event: Command Complete (0x0e) plen 6 > #18 [hci0] 17.307215 Read Voice Setting (0x03|0x0025) ncmd 1 Status: Success (0x00) Setting: 0x0060 Input Coding: Linear Input Data Format: 2's complement Input Sample Size: 16-bit # of bits padding at MSB: 0 Air Coding Format: CVSD < HCI Command: Read Number of Supported IAC (0x03|0x0038) plen 0 #19 [hci0] 17.307235 > HCI Event: Command Complete (0x0e) plen 5 > #20 [hci0] 17.311210 Read Number of Supported IAC (0x03|0x0038) ncmd 1 Status: Success (0x00) Number of IAC: 2 < HCI Command: Read Current IAC LAP (0x03|0x0039) plen 0 #21 [hci0] 17.311230 > HCI Event: Command Complete (0x0e) plen 8 > #22 [hci0] 17.313214 Read Current IAC LAP (0x03|0x0039) ncmd 1 Status: Success (0x00) Number of IAC: 1 Access code: 0x9e8b33 (General Inquiry) < HCI Command: Set Event Filter (0x03|0x0005) plen 1 #23 [hci0] 17.313230 Type: Clear All Filters (0x00) > HCI Event: Command Complete (0x0e) plen 4 > #24 [hci0] 17.316211 Set Event Filter (0x03|0x0005) ncmd 1 Status: Success (0x00) < HCI Command: Write Connection Accept Timeout (0x03|0x0016) plen 2 #25 [hci0] 17.316223 Timeout: 20000.000 msec (0x7d00) > HCI Event: Command Complete (0x0e) plen 4 > #26 [hci0] 17.319210 Write Connection Accept Timeout (0x03|0x0016) ncmd 1 Status: Success (0x00) < HCI Command: Read Local Supported Commands (0x04|0x0002) plen 0 #27 [hci0] 17.319221 > HCI Event: Command Complete (0x0e) plen 68 > #28 [hci0] 17.327209 Read Local Supported Commands (0x04|0x0002) ncmd 1 Status: Success (0x00) Commands: 109 entries Inquiry (Octet 0 - Bit 0) Inquiry Cancel (Octet 0 - Bit 1) Periodic Inquiry Mode (Octet 0 - Bit 2) Exit Periodic Inquiry Mode (Octet 0 - Bit 3) Create Connection (Octet 0 - Bit 4) Disconnect (Octet 0 - Bit 5) Add SCO Connection (Octet 0 - Bit 6) Accept Connection Request (Octet 1 - Bit 0) Reject Connection Request (Octet 1 - Bit 1) Link Key Request Reply (Octet 1 - Bit 2) Link Key Request Negative Reply (Octet 1 - Bit 3) PIN Code Request Reply (Octet 1 - Bit 4) PIN Code Request Negative Reply (Octet 1 - Bit 5) Change Connection Packet Type (Octet 1 - Bit 6) Authentication Requested (Octet 1 - Bit 7) Set Connection Encryption (Octet 2 - Bit 0) Change Connection Link Key (Octet 2 - Bit 1) Master Link Key (Octet 2 - Bit 2) Remote Name Request (Octet 2 - Bit 3) Read Remote Supported Features (Octet 2 - Bit 5) Read Remote Extended Features (Octet 2 - Bit 6) Read Remote Version Information (Octet 2 - Bit 7) Read Clock Offset (Octet 3 - Bit 0) Read LMP Handle (Octet 3 - Bit 1) Hold Mode (Octet 4 - Bit 1) Sniff Mode (Octet 4 - Bit 2) Exit Sniff Mode (Octet 4 - Bit 3) QoS Setup (Octet 4 - Bit 6) Role Discovery (Octet 4 - Bit 7) Switch Role (Octet 5 - Bit 0) Read Link Policy Settings (Octet 5 - Bit 1) Write Link Policy Settings (Octet 5 - Bit 2) Read Default Link Policy Settings (Octet 5 - Bit 3) Write Default Link Policy Settings (Octet 5 - Bit 4) Set Event Mask (Octet 5 - Bit 6) Reset (Octet 5 - Bit 7) Set Event Filter (Octet 6 - Bit 0) Flush (Octet 6 - Bit 1) Read PIN Type (Octet 6 - Bit 2) Write PIN Type (Octet 6 - Bit 3) Create New Unit Key (Octet 6 - Bit 4) Read Stored Link Key (Octet 6 - Bit 5) Write Stored Link Key (Octet 6 - Bit 6) Delete Stored Link Key (Octet 6 - Bit 7) Write Local Name (Octet 7 - Bit 0) Read Local Name (Octet 7 - Bit 1) Read Connection Accept Timeout (Octet 7 - Bit 2) Write Connection Accept Timeout (Octet 7 - Bit 3) Read Page Timeout (Octet 7 - Bit 4) Write Page Timeout (Octet 7 - Bit 5) Read Scan Enable (Octet 7 - Bit 6) Write Scan Enable (Octet 7 - Bit 7) Read Page Scan Activity (Octet 8 - Bit 0) Write Page Scan Activity (Octet 8 - Bit 1) Read Inquiry Scan Activity (Octet 8 - Bit 2) Write Inquiry Scan Activity (Octet 8 - Bit 3) Read Authentication Enable (Octet 8 - Bit 4) Write Authentication Enable (Octet 8 - Bit 5) Read Encryption Mode (Octet 8 - Bit 6) Write Encryption Mode (Octet 8 - Bit 7) Read Class of Device (Octet 9 - Bit 0) Write Class of Device (Octet 9 - Bit 1) Read Voice Setting (Octet 9 - Bit 2) Write Voice Setting (Octet 9 - Bit 3) Read Automatic Flush Timeout (Octet 9 - Bit 4) Write Automatic Flush Timeout (Octet 9 - Bit 5) Read Num Broadcast Retransmissions (Octet 9 - Bit 6) Write Num Broadcast Retransmissions (Octet 9 - Bit 7) Read Hold Mode Activity (Octet 10 - Bit 0) Write Hold Mode Activity (Octet 10 - Bit 1) Read Transmit Power Level (Octet 10 - Bit 2) Read Sync Flow Control Enable (Octet 10 - Bit 3) Write Sync Flow Control Enable (Octet 10 - Bit 4) Set Controller To Host Flow Control (Octet 10 - Bit 5) Host Buffer Size (Octet 10 - Bit 6) Host Number of Completed Packets (Octet 10 - Bit 7) Read Link Supervision Timeout (Octet 11 - Bit 0) Write Link Supervision Timeout (Octet 11 - Bit 1) Read Number of Supported IAC (Octet 11 - Bit 2) Read Current IAC LAP (Octet 11 - Bit 3) Write Current IAC LAP (Octet 11 - Bit 4) Set AFH Host Channel Classification (Octet 12 - Bit 1) Read Inquiry Scan Type (Octet 12 - Bit 4) Write Inquiry Scan Type (Octet 12 - Bit 5) Read Inquiry Mode (Octet 12 - Bit 6) Write Inquiry Mode (Octet 12 - Bit 7) Read Page Scan Type (Octet 13 - Bit 0) Write Page Scan Type (Octet 13 - Bit 1) Read AFH Channel Assessment Mode (Octet 13 - Bit 2) Write AFH Channel Assessment Mode (Octet 13 - Bit 3) Read Local Version Information (Octet 14 - Bit 3) Read Local Supported Commands (Octet 14 - Bit 4) Read Local Supported Features (Octet 14 - Bit 5) Read Local Extended Features (Octet 14 - Bit 6) Read Buffer Size (Octet 14 - Bit 7) Read Country Code (Octet 15 - Bit 0) Read BD ADDR (Octet 15 - Bit 1) Read Failed Contact Counter (Octet 15 - Bit 2) Reset Failed Contact Counter (Octet 15 - Bit 3) Read Link Quality (Octet 15 - Bit 4) Read RSSI (Octet 15 - Bit 5) Read AFH Channel Map (Octet 15 - Bit 6) Read Clock (Octet 15 - Bit 7) Read Loopback Mode (Octet 16 - Bit 0) Write Loopback Mode (Octet 16 - Bit 1) Enable Device Under Test Mode (Octet 16 - Bit 2) Setup Synchronous Connection (Octet 16 - Bit 3) Accept Synchronous Connection Request (Octet 16 - Bit 4) Reject Synchronous Connection Request (Octet 16 - Bit 5) < HCI Command: Set Event Mask (0x03|0x0001) plen 8 #29 [hci0] 17.327247 Mask: 0x00000001fffbffff Inquiry Complete Inquiry Result Connection Complete Connection Request Disconnection Complete Authentication Complete Remote Name Request Complete Encryption Change Change Connection Link Key Complete Master Link Key Complete Read Remote Supported Features Complete Read Remote Version Information Complete QoS Setup Complete Command Complete Command Status Hardware Error Flush Occurred Role Change Mode Change Return Link Keys PIN Code Request Link Key Request Link Key Notification Loopback Command Data Buffer Overflow Max Slots Change Read Clock Offset Complete Connection Packet Type Changed QoS Violation Page Scan Mode Change Page Scan Repetition Mode Change Flow Specification Complete > HCI Event: Command Complete (0x0e) plen 4 > #30 [hci0] 17.329211 Set Event Mask (0x03|0x0001) ncmd 1 Status: Success (0x00) < HCI Command: Read Stored Link Key (0x03|0x000d) plen 7 #31 [hci0] 17.329225 Address: 00:00:00:00:00:00 (OUI 00-00-00) Read all: 0x01 > HCI Event: Command Complete (0x0e) plen 8 > #32 [hci0] 17.332214 @lsusb -v Bus 005 Device 005: ID 0a12:0001 Cambridge Silicon Radio, Ltd Bluetooth Dongle (HCI mode) Couldn't open device, some information will be missing Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 224 Wireless bDeviceSubClass 1 Radio Frequency bDeviceProtocol 1 Bluetooth bMaxPacketSize0 16 idVendor 0x0a12 Cambridge Silicon Radio, Ltd idProduct 0x0001 Bluetooth Dongle (HCI mode) bcdDevice 1.34 iManufacturer 1 iProduct 2 iSerial 0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 0x006c bNumInterfaces 2 bConfigurationValue 1 iConfiguration 0 bmAttributes 0x80 (Bus Powered) MaxPower 100mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 3 bInterfaceClass 224 Wireless bInterfaceSubClass 1 Radio Frequency bInterfaceProtocol 1 Bluetooth iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0010 1x 16 bytes bInterval 1 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x82 EP 2 IN bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0040 1x 64 bytes bInterval 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x02 EP 2 OUT bmAttributes 2 Transfer Type Bulk Synch Type None Usage Type Data wMaxPacketSize 0x0040 1x 64 bytes bInterval 0 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 1 bAlternateSetting 0 bNumEndpoints 2 bInterfaceClass 224 Wireless bInterfaceSubClass 1 Radio Frequency bInterfaceProtocol 1 Bluetooth iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x83 EP 3 IN bmAttributes 1 Transfer Type Isochronous Synch Type None Usage Type Data wMaxPacketSize 0x0000 1x 0 bytes bInterval 1 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x03 EP 3 OUT bmAttributes 1 Transfer Type Isochronous Synch Type None Usage Type Data wMaxPacketSize 0x0000 1x 0 bytes bInterval 1 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 1 bAlternateSetting 1 bNumEndpoints 2 bInterfaceClass 224 Wireless bInterfaceSubClass 1 Radio Frequency bInterfaceProtocol 1 Bluetooth iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x83 EP 3 IN bmAttributes 1 Transfer Type Isochronous Synch Type None Usage Type Data wMaxPacketSize 0x0009 1x 9 bytes bInterval 1 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x03 EP 3 OUT bmAttributes 1 Transfer Type Isochronous Synch Type None Usage Type Data wMaxPacketSize 0x0009 1x 9 bytes bInterval 1 Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 1 bAlternateSetting 2 bNumEndpoints 2 bInterfaceClass 224 Wireless bInterfaceSubClass 1 Radio Frequency bInterfaceProtocol 1 Bluetooth iInterface 0 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x83 EP 3 IN bmAttributes 1 Transfer Type Isochronous Synch Type None Usage Type Data wMaxPacketSize 0x0011 1x 17 bytes bInterval 1 Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x03 EP 3 OUT bmAttributes 1 Transfer Type Isochronous Synch Type None Usage Type Data wMaxPacketSize 0x0011 1x 17 bytes bInterval 1 Read Stored Link Key (0x03|0x000d) ncmd 1 Status: Unsupported Feature or Parameter Value (0x11) Max num keys: 0 Num keys: 0 = Close Index: 00:11:67:55:8F:C3 [hci0] 17.332241 @ RAW Close: hciconfig -- You are receiving this mail because: You are the assignee for the bug.