This is basically a copy of cmd_bind with OP_MODEL_APP_BIND replaced by OP_MODEL_APP_UNBIND as cmds[] already has code to handle it. --- tools/mesh/cfgcli.c | 36 ++++++++++++++++++++++++++++++++++++ 1 file changed, 36 insertions(+) diff --git a/tools/mesh/cfgcli.c b/tools/mesh/cfgcli.c index 086998910..a4de42943 100644 --- a/tools/mesh/cfgcli.c +++ b/tools/mesh/cfgcli.c @@ -897,6 +897,40 @@ static void cmd_bind(int argc, char *argv[]) return bt_shell_noninteractive_quit(EXIT_SUCCESS); } +static void cmd_unbind(int argc, char *argv[]) +{ + uint16_t n; + uint8_t msg[32]; + int parm_cnt; + + parm_cnt = read_input_parameters(argc, argv); + if (parm_cnt != 3 && parm_cnt != 4) { + bt_shell_printf("Bad arguments\n"); + return bt_shell_noninteractive_quit(EXIT_FAILURE); + } + + n = mesh_opcode_set(OP_MODEL_APP_UNBIND, msg); + + put_le16(parms[0], msg + n); + n += 2; + put_le16(parms[1], msg + n); + n += 2; + + if (parm_cnt == 4) { + put_le16(parms[3], msg + n); + put_le16(parms[2], msg + n + 2); + n += 4; + } else { + put_le16(parms[2], msg + n); + n += 2; + } + + if (!config_send(msg, n, OP_MODEL_APP_UNBIND)) + return bt_shell_noninteractive_quit(EXIT_FAILURE); + + return bt_shell_noninteractive_quit(EXIT_SUCCESS); +} + static void cmd_beacon_set(int argc, char *argv[]) { uint16_t n; @@ -1335,6 +1369,8 @@ static const struct bt_shell_menu cfg_menu = { "Delete application key"}, {"bind", "<ele_addr> <app_idx> <mod_id> [vendor_id]", cmd_bind, "Bind app key to a model"}, + {"unbind", "<ele_addr> <app_idx> <mod_id> [vendor_id]", cmd_unbind, + "Remove app key from a model"}, {"mod-appidx-get", "<ele_addr> <model id>", cmd_mod_appidx_get, "Get model app_idx"}, {"ttl-set", "<ttl>", cmd_ttl_set, -- 2.24.0