Hi Luiz, Sorry, I have another thing in my my mind. DEFAULT_TTL was set to 0xFF (not 0x77) and this is out of valid range(my device does not acknowledge the message). I will follow with V2. About the extra formatting - I just took as a example the pub-set command. with extra formatting config help looks like : relay-get Get relay hb-pub-set <pub_addr> <count> <period> <ttl> <features> <net_idx> Set heartbeat publish hb-pub-get Get heartbeat publish without extra formatting: relay-get Get relay hb-pub-set <pub_addr> <count> <period> <ttl> <features> <net_idx> Set heartbeat publish hb-pub-get Get heartbeat publish What do you think? Robert 2018-03-21 19:39 GMT+01:00 Luiz Augusto von Dentz <luiz.dentz@xxxxxxxxx>: > Hi Robert, > > On Wed, Mar 21, 2018 at 6:59 PM, Robert Lubaś <robert.lubas@xxxxxxxxxxx> wrote: >> In 4.2.17.4 Heartbeat Publication TTL value range is 0x00-0x7F. >> In cmd_hb_pub_set heartbeat ttl was set to DEFAULT_TTL 0x77, this >> patch fix this by adding ttl param to hb-pub-set. > > I don't follow, is 0x77 not valid? It should be if the range is really > 0x00-0x7F. > >> --- >> mesh/config-client.c | 13 +++++++------ >> 1 file changed, 7 insertions(+), 6 deletions(-) >> >> diff --git a/mesh/config-client.c b/mesh/config-client.c >> index 19e617d62..9757e2625 100644 >> --- a/mesh/config-client.c >> +++ b/mesh/config-client.c >> @@ -1042,7 +1042,7 @@ static void cmd_hb_pub_set(int argc, char *argv[]) >> n = mesh_opcode_set(OP_CONFIG_HEARTBEAT_PUB_SET, msg); >> >> parm_cnt = read_input_parameters(argc, argv); >> - if (parm_cnt != 5) { >> + if (parm_cnt != 6) { >> bt_shell_printf("Bad arguments: %s\n", argv[1]); >> return bt_shell_noninteractive_quit(EXIT_FAILURE); >> } >> @@ -1056,12 +1056,12 @@ static void cmd_hb_pub_set(int argc, char *argv[]) >> /* Period Log */ >> msg[n++] = parms[2]; >> /* Heartbeat TTL */ >> - msg[n++] = DEFAULT_TTL; >> + msg[n++] = parms[3]; >> /* Features */ >> - put_le16(parms[3], msg + n); >> + put_le16(parms[4], msg + n); >> n += 2; >> /* NetKey Index */ >> - put_le16(parms[4], msg + n); >> + put_le16(parms[5], msg + n); >> n += 2; >> >> if (!config_send(msg, n)) { >> @@ -1167,8 +1167,9 @@ static const struct bt_shell_menu cfg_menu = { >> "Set relay"}, >> {"relay-get", NULL, cmd_relay_get, >> "Get relay"}, >> - {"hb-pub-set", "<pub_addr> <count> <period> <features> <net_idx>", >> - cmd_hb_pub_set, "Set heartbeat publish"}, >> + {"hb-pub-set", "<pub_addr> <count> <period> <ttl> <features> " >> + "<net_idx>", >> + cmd_hb_pub_set, "\n\t\t\t\t\t\t Set heartbeat publish"}, > > I don't really like the idea of having extra formatting on the command > description, bt_shell should do the right thing and if that doesn't > fit in the terminal it should wrap around automatically. > >> {"hb-pub-get", NULL, cmd_hb_pub_get, >> "Get heartbeat publish"}, >> {"hb-sub-set", "<src_addr> <dst_addr> <period>", >> -- >> 2.11.0 >> >> -- >> To unsubscribe from this list: send the line "unsubscribe linux-bluetooth" in >> the body of a message to majordomo@xxxxxxxxxxxxxxx >> More majordomo info at http://vger.kernel.org/majordomo-info.html > > > > -- > Luiz Augusto von Dentz -- Robert Lubaś Software Developer Silvair by Seed Labs Jasnogórska 44 31-358 Krakow POLAND www.silvair.com -- To unsubscribe from this list: send the line "unsubscribe linux-bluetooth" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html