Re: Issue with new LE connection creation

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi,

> so when I try to connect a LE L2CAP connection to a device that does not exist and then abort it will not have reached the timeout, I get this:
> 
> < HCI Command: LE Add Device To White List (0x08|0x0011) plen 7
>        Address type: Public (0x00)
>        Address: 11:22:33:44:55:66 (OUI 11-22-33)
>> HCI Event: Command Complete (0x0e) plen 4
>      LE Add Device To White List (0x08|0x0011) ncmd 1
>        Status: Success (0x00)
> < HCI Command: LE Set Scan Parameters (0x08|0x000b) plen 7
>        Type: Passive (0x00)
>        Interval: 60.000 msec (0x0060)
>        Window: 30.000 msec (0x0030)
>        Own address type: Public (0x00)
>        Filter policy: Ignore not in white list (0x01)
>> HCI Event: Command Complete (0x0e) plen 4
>      LE Set Scan Parameters (0x08|0x000b) ncmd 1
>        Status: Success (0x00)
> < HCI Command: LE Set Scan Enable (0x08|0x000c) plen 2
>        Scanning: Enabled (0x01)
>        Filter duplicates: Enabled (0x01)
>> HCI Event: Command Complete (0x0e) plen 4
>      LE Set Scan Enable (0x08|0x000c) ncmd 1
>        Status: Success (0x00)
> < HCI Command: LE Set Scan Enable (0x08|0x000c) plen 2
>        Scanning: Disabled (0x00)
>        Filter duplicates: Disabled (0x00)
>> HCI Event: Command Complete (0x0e) plen 4
>      LE Set Scan Enable (0x08|0x000c) ncmd 1
>        Status: Success (0x00)
> < HCI Command: LE Set Scan Enable (0x08|0x000c) plen 2
>        Scanning: Disabled (0x00)
>        Filter duplicates: Disabled (0x00)
>> HCI Event: Command Complete (0x0e) plen 4
>      LE Set Scan Enable (0x08|0x000c) ncmd 1
>        Status: Command Disallowed (0x0c)
> 
> Notice the two attempts for disabling scanning. We should not do that. This is clearly a bug. This can be easily reproduced with latest bluetooth-next and this command:
> 
> l2test -V le_public -n 11:22:33:44:55:66
> 
> The same happens when you are waiting for the socket connect timeout. The scanning disable command is sent twice.
> 
> I also had a case where the disabling of the scanning is not sent at all and the controller kept scanning. However for that one, I do not have an easy way to reproduce it. But it is essentially the same case, you close the socket / application before the connection has been established.

in addition when a connect() for LE L2CAP socket call times out, we get an invalid module reference count.

bluetooth             532480  1
rfkill                 24576  1 bluetooth

I see it left with an extra reference count. This is pretty bad and shows that something is clearly wrong.

Regards

Marcel

--
To unsubscribe from this list: send the line "unsubscribe linux-bluetooth" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html



[Index of Archives]     [Bluez Devel]     [Linux Wireless Networking]     [Linux Wireless Personal Area Networking]     [Linux ATH6KL]     [Linux USB Devel]     [Linux Media Drivers]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [Big List of Linux Books]

  Powered by Linux