Hi Anderson, > > I'm not sure if I understand correctly. But do you mean the GCEP you > > mentioned above is applied while "reconnecting" to a supported device? > > Yes, all GAP connection procedures are applicable for re-connection. > There is no "reconnection" procedure as per GAP (as far as I know). > But note that each GATT profile can specify reconnection procedures in > case of disconnection due to link loss (most of those that I read have > this). For instance, in HTP: > > "5.2.4 Link Loss Reconnection Procedure > When a connection is terminated due to link loss, a Collector should > attempt to reconnect to the Thermometer using any of the GAP connection > procedures with the parameters in Table 5.2." > > This is what BlueZ is doing for profiles implemented internally, except > that the parameters we use are not the ones recommended on the profile > specs (that could be implemented in future, but for now GCEP uses fixed > connection parameters). > So I should exercise the D-Bus API like following for LE device: Adapter1.StartDiscovery Device1.Pair ... ... // link loss ... // auto reconnect ... Adapter1.RemoveDevice Is my understanding correct? Thank you, Ting -- To unsubscribe from this list: send the line "unsubscribe linux-bluetooth" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html