Hi Anderson,
On 09/25/2012 05:21 PM, Anderson Lizardo wrote:
Hi Andrzej,
On Tue, Sep 25, 2012 at 10:52 AM, Andrzej Kaczmarek
<andrzej.kaczmarek@xxxxxxxxx> wrote:
Hi,
Here's series of patches to move watchers from per-device to per-adapter
interface (basically the same as done for HRP, see other series of patches).
This applies to both final and intermediate temperature watchers - once
watcher is registered, all connected devices are setup to send measurement
notifications and the opposite when last watcher is unregistered.
This major change is done in patches 1-6.
Patches 7-11 contain some code and documentation refactoring, i.e. to
remove duplicated code.
Patches 12-14 are trival coding style fixes.
Unfortunately, I wasn't able to fully test this code due to lack of proper
thermometer device and sample device from CC2540 devkit does not quite
work as expected (e.g. I can see CCC is written properly when watcher is
registered but remote does not send any indications for unknown reason).
Unfortunately, the thermometer demo app (at least on TI's BLE stack
v1.1 installation) has several bugs. I haven't tested yet the latest
release (1.2.1), which version are you using?
1.2 but downloaded 1.2.1 and thermometer demo app didn't change so it
still does not work.
Do you have access to PTS? You could test with it as well.
I currently don't have BLE dongle for PTS but will test as soon as I
have one.
Maybe we should consider implementing a simple Thermometer role in
BlueZ for testing purposes. It is a relatively simple profile.
So you mean something like optional org.bluez.ThermometerSensor
interface on adapter, similar to what is done for reporter role for
Proximity?
BR,
Andrzej
--
To unsubscribe from this list: send the line "unsubscribe linux-bluetooth" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html