Hi, The hcidump program shows a remote name request "Page Timeout" error. I do not understand the reason. The Bluez stack requests for remote name, the device replied with 'Nonin_Medical_Inc._359443' twice, Then Bluez stack requests again, got "Page Timeout" error, and connection stops. What is the reason of this behavior? Thanks, Victor < HCI Command: Remote Name Request (0x01|0x0019) plen 10 bdaddr 00:1C:05:00:70:44 mode 2 clkoffset 0x0000 > HCI Event: Command Status (0x0f) plen 4 Remote Name Request (0x01|0x0019) status 0x00 ncmd 1 > HCI Event: Remote Name Req Complete (0x07) plen 255 status 0x00 bdaddr 00:1C:05:00:70:44 name 'Nonin_Medical_Inc._359443' < HCI Command: Remote Name Request (0x01|0x0019) plen 10 bdaddr 00:1C:05:00:70:44 mode 2 clkoffset 0x0000 > HCI Event: Command Status (0x0f) plen 4 Remote Name Request (0x01|0x0019) status 0x00 ncmd 1 > HCI Event: Remote Name Req Complete (0x07) plen 255 status 0x00 bdaddr 00:1C:05:00:70:44 name 'Nonin_Medical_Inc._359443' < HCI Command: Remote Name Request (0x01|0x0019) plen 10 bdaddr 00:1C:05:00:70:44 mode 2 clkoffset 0x0000 > HCI Event: Command Status (0x0f) plen 4 Remote Name Request (0x01|0x0019) status 0x00 ncmd 1 > HCI Event: Remote Name Req Complete (0x07) plen 255 status 0x04 bdaddr 00:1C:05:00:70:44 name '' Error: Page Timeout -- To unsubscribe from this list: send the line "unsubscribe linux-bluetooth" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html