Re: [PATCH BlueZ 1/1] Set `SDP_LARGE_MTU` flag for DS4 Rev. 2 product code

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi Kieran,

On Thu, Dec 19, 2024 at 1:13 PM Kieran Geary <kieran.r.geary@xxxxxxxxx> wrote:
>
> ---
>  src/device.c | 2 +-
>  1 file changed, 1 insertion(+), 1 deletion(-)
>
> diff --git a/src/device.c b/src/device.c
> index 2b3d19f55..4e5a5b945 100644
> --- a/src/device.c
> +++ b/src/device.c
> @@ -6047,7 +6047,7 @@ static uint16_t get_sdp_flags(struct btd_device *device)
>          * results in SDP response being dropped by kernel. Workaround this by
>          * forcing SDP code to use bigger MTU while connecting.
>          */
> -       if (vid == 0x054c && pid == 0x05c4)
> +       if (vid == 0x054c && (pid == 0x05c4 || pid == 0x09cc))
>                 return SDP_LARGE_MTU;
>
>         if (btd_adapter_ssp_enabled(device->adapter))
> --
> 2.47.1

Perhaps it would be a good idea to create a vid:pid table if there are
multiple devices being affected.

-- 
Luiz Augusto von Dentz





[Index of Archives]     [Bluez Devel]     [Linux Wireless Networking]     [Linux Wireless Personal Area Networking]     [Linux ATH6KL]     [Linux USB Devel]     [Linux Media Drivers]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [Big List of Linux Books]