Hi Luiz, On our DUT, we can see that the host issues create connection cancel command after 4-sec if there is no connection complete event for LE create connection cmd. As per core spec v5.3 section 7.8.5, advertisement interval range is - Advertising_Interval_Min Default : 0x0800(1.28s) Time Range: 20ms to 10.24s Advertising_Interval_Max Default : 0x0800(1.28s) Time Range: 20ms to 10.24s If the remote device is using adv interval of > 4 sec, it is difficult to make a connection with the current timeout value. Also, with the default interval of 1.28 sec, we will get only 3 chances to capture the adv packets with the 4 sec window. Hence we want to increase this timeout to 20sec. Note: In Android this timeout value is 29 secs. Does setting via 'conn->conn_timeout' mean setting 'Autoconnecttimeout=value' in main.conf file? Thanks and regards, Mahesh Vithal Talewad -----Original Message----- From: Luiz Augusto von Dentz <luiz.dentz@xxxxxxxxx> Sent: Wednesday, March 20, 2024 5:13 PM To: Mahesh Talewad <mahesh.talewad@xxxxxxx> Cc: linux-bluetooth@xxxxxxxxxxxxxxx; Devyani Godbole <devyani.godbole@xxxxxxx>; Sarveshwar Bajaj <sarveshwar.bajaj@xxxxxxx> Subject: Re: [EXT] Re: [PATCH BlueZ v1 1/1] LE Create Connection command timeout increased to 20 secs from 4 secs Caution: This is an external email. Please take care when clicking links or opening attachments. When in doubt, report the message using the 'Report this email' button Hi Mahesh, On Wed, Mar 20, 2024 at 10:56 AM Mahesh Talewad <mahesh.talewad@xxxxxxx> wrote: > > Hi Luiz, > > Yes, its auto connect scenario. > While running connect disconnect in a loop on one of the chip, we are getting issue with this default timeout . Hence we increased this timeout value to standard LE timeout i.e 20s. > Kindly let us know, is there any timeout explicitly defined for the autoconnect in the spec. What exactly is the issue though, or are you saying it is a controller issue because the attempts are too closely together when the timeout is just 4 seconds, note that you are just working around the problem because users can bypass the default when set via conn->conn_timeout. > Thanks and regards, > Mahesh Vithal Talewad > > -----Original Message----- > From: Luiz Augusto von Dentz <luiz.dentz@xxxxxxxxx> > Sent: Wednesday, March 20, 2024 3:21 PM > To: Mahesh Talewad <mahesh.talewad@xxxxxxx> > Cc: linux-bluetooth@xxxxxxxxxxxxxxx; Devyani Godbole > <devyani.godbole@xxxxxxx>; Sarveshwar Bajaj <sarveshwar.bajaj@xxxxxxx> > Subject: [EXT] Re: [PATCH BlueZ v1 1/1] LE Create Connection command > timeout increased to 20 secs from 4 secs > > Caution: This is an external email. Please take care when clicking > links or opening attachments. When in doubt, report the message using > the 'Report this email' button > > > Hi Mahesh, > > On Mon, Mar 18, 2024 at 12:37 PM Mahesh Talewad <mahesh.talewad@xxxxxxx> wrote: > > > > - As per specs LE Connection timeout is 20 secs but in implementation, > > it was 4 secs. Hence increased this timeout to 20 Secs. > > > > Signed-off-by: Mahesh Talewad <mahesh.talewad@xxxxxxx> > > --- > > net/bluetooth/hci_event.c | 2 +- > > 1 file changed, 1 insertion(+), 1 deletion(-) > > > > diff --git a/net/bluetooth/hci_event.c b/net/bluetooth/hci_event.c > > index 4ae224824012..06fe5f6b9546 100644 > > --- a/net/bluetooth/hci_event.c > > +++ b/net/bluetooth/hci_event.c > > @@ -6067,7 +6067,7 @@ static struct hci_conn *check_pending_le_conn(struct hci_dev *hdev, > > } > > > > conn = hci_connect_le(hdev, addr, addr_type, addr_resolved, > > - BT_SECURITY_LOW, hdev->def_le_autoconnect_timeout, > > + BT_SECURITY_LOW, HCI_LE_CONN_TIMEOUT, > > HCI_ROLE_MASTER); > > if (!IS_ERR(conn)) { > > /* If HCI_AUTO_CONN_EXPLICIT is set, conn is already > > owned > > -- > > 2.34.1 > > Afaik this is on purpose since it is the autoconnect procedure, rather than user initiate connection, so are you running into a problem if the timeout is different? > > -- > Luiz Augusto von Dentz -- Luiz Augusto von Dentz