Hi Brian,

On Wed, Jan 26, 2011 at 9:58 AM, Anderson Lizardo
<anderson.lizardo@xxxxxxxxxxxxx> wrote:
> On Wed, Jan 26, 2011 at 9:33 AM, Anderson Lizardo
> <anderson.lizardo@xxxxxxxxxxxxx> wrote:
>> Looks like more a PTS bug, but makes me wonder if it is not better for
>> BlueZ to have separate procedures instead of this "automatic" usage of
>> read blob request ?
>
> BTW, the test which presented this issue with sending spurious read
> blob request is named "Read Characteristic Descriptors – by client". I
> also can see that the behavior you implemented satisfies both "Read
> Long Characteristic Value - by client" and "Read Long Characteristic
> Descriptor - by client" tests. All theses tests come from the GATT TS
> document.

Another update... Test "Read Long Characteristic Value – Invalid
handle" expects a Read Blob request specifically. The only way I see
to satisfy it is to provide a separate "read long characteristic
value" procedure separate from the "read characteristic value". Any
other ideas?

Regards,
-- 
Anderson Lizardo
OpenBossa Labs - INdT
Manaus - Brazil
--
To unsubscribe from this list: send the line "unsubscribe linux-bluetooth" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html


[Index of Archives]     [Bluez Devel]     [Linux Wireless Networking]     [Linux Wireless Personal Area Networking]     [Linux ATH6KL]     [Linux USB Devel]     [Linux Media Drivers]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [Big List of Linux Books]

  Powered by Linux