[PATCH] Fix plugin close & disconnect functions call order

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



From: Slawomir Bochenski <lkslawek@xxxxxxxxx>

Normally during an OBEX session, calling sequence

service->connect - [driver->open - driver->close]* - service->disconnect

is kept. The only exception to this when the connection is reset
(when no ABORT was sent) during transfer. Then the sequence is:

service->connect - [driver->open - driver->close]* - driver->open -
service->disconnect - driver->close

This patch fixes it, so memory managament of session/transfer data in
service plugin can be easier.
---
 src/obex.c |    2 ++
 1 files changed, 2 insertions(+), 0 deletions(-)

diff --git a/src/obex.c b/src/obex.c
index 65f17fc..67684fa 100644
--- a/src/obex.c
+++ b/src/obex.c
@@ -1231,6 +1231,8 @@ static void obex_handle_destroy(void *user_data)
 
 	os = OBEX_GetUserData(obex);
 
+	os_reset_session(os);
+
 	if (os->service && os->service->disconnect)
 		os->service->disconnect(os, os->service_data);
 
-- 
1.7.1

--
To unsubscribe from this list: send the line "unsubscribe linux-bluetooth" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html