> On 6 Nov 2020, at 15.14, Christoph Hellwig <hch@xxxxxx> wrote: > > >> >> +#ifdef CONFIG_BLK_DEV_ZONED >> + if (blk_queue_is_zoned(disk->queue) && !ns->zoned_ns_supp) >> + set_disk_ro(disk, true); >> +#endif > > I think we can simplify this at bit. Add a new NVME_NS_FORCE_RO flag > to ns->flags, set it in nvme_update_zone_info, and just query it here > without any ifdefs. > >> struct request_queue *q = disk->queue; >> struct nvme_command c = { }; >> struct nvme_id_ns_zns *id; >> + bool zoned_ns_supp = true; >> int status; >> >> /* Driver requires zone append support */ >> if (!(le32_to_cpu(log->iocs[nvme_cmd_zone_append]) & >> NVME_CMD_EFFECTS_CSUPP)) { >> + zoned_ns_supp = false; >> dev_warn(ns->ctrl->device, >> "append not supported for zoned namespace:%d\n", >> ns->head->ns_id); >> + } else { >> + /* Lazily query controller append limit for the first >> + * zoned namespace >> + */ >> + if (!ns->ctrl->max_zone_append) { >> + status = nvme_set_max_append(ns->ctrl); >> + if (status) >> + return status; >> + } > > While you're at it: my inverse the polarity of the if check as that reads just > a little more natural, and maybe mention in the warning that the namespace is > forced to read-only mode? > > Otherwise this looks good. Thanks. I’ll send a V2.