Quoting Kuogee Hsieh (2021-07-13 08:54:01) > DP cable should always connect to DPU during the entire PHY compliance > testing run. Since DP PHY compliance test is executed at irq_hpd event > context, dp_ctrl_off_link_stream() should be used instead of dp_ctrl_off(). > dp_ctrl_off() is used for unplug event which is triggered when DP cable is > dis connected. > > Changes in V2: > -- add fixes statement > > Fixes: f21c8a276c2d ("drm/msm/dp: handle irq_hpd with sink_count = 0 correctly") > > Signed-off-by: Kuogee Hsieh <khsieh@xxxxxxxxxxxxxx> > --- Reviewed-by: Stephen Boyd <swboyd@xxxxxxxxxxxx>