[Patch v2 5/5] arm64: boot: dts: qcom: sdm845: Remove passive trip points for thermal zones 0-7

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Now that Limits h/w is enabled to monitor thermal events around cpus and
throttle the cpu frequencies, remove cpufreq cooling device for the cpus which
does software throttling of cpu frequencies.

Signed-off-by: Thara Gopinath <thara.gopinath@xxxxxxxxxx>
---

v1->v2:
	Removing only cooling maps for cpu specific thermal zones keeping the
	trip point definitions intact as per Daniel's suggestion. This is to
	ensure that thermal zone temparature and trip violation information is
	available to any userspace daemon monitoring these zones.

 arch/arm64/boot/dts/qcom/sdm845.dtsi | 136 ---------------------------
 1 file changed, 136 deletions(-)

diff --git a/arch/arm64/boot/dts/qcom/sdm845.dtsi b/arch/arm64/boot/dts/qcom/sdm845.dtsi
index 202fec09becd..7819f87d97ac 100644
--- a/arch/arm64/boot/dts/qcom/sdm845.dtsi
+++ b/arch/arm64/boot/dts/qcom/sdm845.dtsi
@@ -4994,23 +4994,6 @@ cpu0_crit: cpu_crit {
 					type = "critical";
 				};
 			};
-
-			cooling-maps {
-				map0 {
-					trip = <&cpu0_alert0>;
-					cooling-device = <&CPU0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-				map1 {
-					trip = <&cpu0_alert1>;
-					cooling-device = <&CPU0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-			};
 		};
 
 		cpu1-thermal {
@@ -5038,23 +5021,6 @@ cpu1_crit: cpu_crit {
 					type = "critical";
 				};
 			};
-
-			cooling-maps {
-				map0 {
-					trip = <&cpu1_alert0>;
-					cooling-device = <&CPU0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-				map1 {
-					trip = <&cpu1_alert1>;
-					cooling-device = <&CPU0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-			};
 		};
 
 		cpu2-thermal {
@@ -5082,23 +5048,6 @@ cpu2_crit: cpu_crit {
 					type = "critical";
 				};
 			};
-
-			cooling-maps {
-				map0 {
-					trip = <&cpu2_alert0>;
-					cooling-device = <&CPU0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-				map1 {
-					trip = <&cpu2_alert1>;
-					cooling-device = <&CPU0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-			};
 		};
 
 		cpu3-thermal {
@@ -5126,23 +5075,6 @@ cpu3_crit: cpu_crit {
 					type = "critical";
 				};
 			};
-
-			cooling-maps {
-				map0 {
-					trip = <&cpu3_alert0>;
-					cooling-device = <&CPU0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-				map1 {
-					trip = <&cpu3_alert1>;
-					cooling-device = <&CPU0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-			};
 		};
 
 		cpu4-thermal {
@@ -5170,23 +5102,6 @@ cpu4_crit: cpu_crit {
 					type = "critical";
 				};
 			};
-
-			cooling-maps {
-				map0 {
-					trip = <&cpu4_alert0>;
-					cooling-device = <&CPU4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-				map1 {
-					trip = <&cpu4_alert1>;
-					cooling-device = <&CPU4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-			};
 		};
 
 		cpu5-thermal {
@@ -5214,23 +5129,6 @@ cpu5_crit: cpu_crit {
 					type = "critical";
 				};
 			};
-
-			cooling-maps {
-				map0 {
-					trip = <&cpu5_alert0>;
-					cooling-device = <&CPU4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-				map1 {
-					trip = <&cpu5_alert1>;
-					cooling-device = <&CPU4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-			};
 		};
 
 		cpu6-thermal {
@@ -5258,23 +5156,6 @@ cpu6_crit: cpu_crit {
 					type = "critical";
 				};
 			};
-
-			cooling-maps {
-				map0 {
-					trip = <&cpu6_alert0>;
-					cooling-device = <&CPU4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-				map1 {
-					trip = <&cpu6_alert1>;
-					cooling-device = <&CPU4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-			};
 		};
 
 		cpu7-thermal {
@@ -5302,23 +5183,6 @@ cpu7_crit: cpu_crit {
 					type = "critical";
 				};
 			};
-
-			cooling-maps {
-				map0 {
-					trip = <&cpu7_alert0>;
-					cooling-device = <&CPU4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-				map1 {
-					trip = <&cpu7_alert1>;
-					cooling-device = <&CPU4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
-							 <&CPU7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-			};
 		};
 
 		aoss0-thermal {
-- 
2.25.1




[Index of Archives]     [Linux ARM Kernel]     [Linux ARM]     [Linux Omap]     [Fedora ARM]     [Linux for Sparc]     [IETF Annouce]     [Security]     [Bugtraq]     [Linux MIPS]     [ECOS]     [Asterisk Internet PBX]     [Linux API]