On Thu, Nov 26, 2020 at 2:16 AM Ansuel Smith <ansuelsmth@xxxxxxxxx> wrote: > > > }; > > > @@ -441,6 +442,10 @@ enum regfield_ids { > > > CRIT_THRESH_14, > > > CRIT_THRESH_15, > > > > > > + /* VER_0 MIN MAX THRESH */ > > > + MIN_THRESH_0, > > > + MAX_THRESH_0, > > > + > > > > Consider reusing LOW_THRESH_0 and UP_THRESH_0 for these? > > > > As we already have defined LOW_THRESH and UP how can we reuse that > regfield to define MIN and MAX? > We are using MIN and MAX THRESH on the apq8064 to mean LOW and UP THRESOLD, isn't it? IIUC, It was just named differently earlier. When the driver is loaded on the apq8064, only that one field will be use since v0 has a single threshold for all sensors. When the driver is loaded on new IPs, all fields will be used.