msm8916 uses sensors 0, 1, 2, 4 and 5. Sensor 3 is NOT used. Fixup the device tree so that the correct sensor ID is used and as a result we can actually check the temperature for the cpu2_3 sensor. Signed-off-by: Amit Kucheria <amit.kucheria@xxxxxxxxxx> Reviewed-by: Daniel Lezcano <daniel.lezcano@xxxxxxxxxx> Reviewed-by: Stephen Boyd <swboyd@xxxxxxxxxxxx> --- arch/arm64/boot/dts/qcom/msm8916.dtsi | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/arch/arm64/boot/dts/qcom/msm8916.dtsi b/arch/arm64/boot/dts/qcom/msm8916.dtsi index 5ea9fb8f2f87d..8686e101905cc 100644 --- a/arch/arm64/boot/dts/qcom/msm8916.dtsi +++ b/arch/arm64/boot/dts/qcom/msm8916.dtsi @@ -179,7 +179,7 @@ polling-delay-passive = <250>; polling-delay = <1000>; - thermal-sensors = <&tsens 4>; + thermal-sensors = <&tsens 5>; trips { cpu0_1_alert0: trip-point@0 { @@ -209,7 +209,7 @@ polling-delay-passive = <250>; polling-delay = <1000>; - thermal-sensors = <&tsens 3>; + thermal-sensors = <&tsens 4>; trips { cpu2_3_alert0: trip-point@0 { -- 2.17.1