[PATCH V2 0/2] Re-initialize DLL when MCLK is gated dynamically

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On few SDHCI-MSM controllers, the host controller's clock tuning
circuit may go out of sync if controller clocks are gated which
eventually, result in data CRC and command CRC/timeout errors.
To fix this issue, the DLL needs to be re-initialized and restored with
its old settings once clocks are ungated.

Changes since V1:
	- Replaced dt flag with a dt compatible string to
	indicate SHDCI-MSM controller varients which need this fix.
	- Moved the DLL settings restoration logic from request 
	context to platform driver runtime pm context.

Tested on: sdm845
Requies patch series:"[PATCH V2 0/3] Internal voltage control for platform drivers"

Veerabhadrarao Badiganti (2):
  dt-bindings: mmc: sdhci-msm: Add new compatible string for sdcdc10 DLL
  mmc: sdhci-msm: Re-initialize DLL if MCLK is gated dynamically

 .../devicetree/bindings/mmc/sdhci-msm.txt          |  4 ++
 drivers/mmc/host/sdhci-msm.c                       | 67 +++++++++++++++++++++-
 2 files changed, 69 insertions(+), 2 deletions(-)

-- 
Qualcomm India Private Limited, on behalf of Qualcomm Innovation Center, Inc.
Qualcomm Innovation Center, Inc. is a member of Code Aurora Forum, a Linux Foundation Collaborative Project.