[PATCH v2 03/11] dt-bindings: thermal: Fix a typo in documentation

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



c(1) + x(1) was actually meant to be c(1) * x(1).

Signed-off-by: Amit Kucheria <amit.kucheria@xxxxxxxxxx>
Reviewed-by: Matthias Kaehlcke <mka@xxxxxxxxxxxx>
Acked-by: Rob Herring <robh@xxxxxxxxxx>
---
 Documentation/devicetree/bindings/thermal/thermal.txt | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt
index eb7ee91556a5..ca14ba959e0d 100644
--- a/Documentation/devicetree/bindings/thermal/thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/thermal.txt
@@ -152,7 +152,7 @@ Optional property:
   Elem size: one cell	the sensors listed in the thermal-sensors property.
   Elem type: signed	Coefficients defaults to 1, in case this property
 			is not specified. A simple linear polynomial is used:
-			Z = c0 * x0 + c1 + x1 + ... + c(n-1) * x(n-1) + cn.
+			Z = c0 * x0 + c1 * x1 + ... + c(n-1) * x(n-1) + cn.
 
 			The coefficients are ordered and they match with sensors
 			by means of sensor ID. Additional coefficients are
-- 
2.17.1