On 11/28/2017 11:29 AM, Sinan Kaya wrote: > On 11/28/2017 10:30 AM, Ville Syrjälä wrote: >>> + dev_priv->bridge_dev = >>> + pci_get_domain_bus_and_slot(domain, 0, PCI_DEVFN(0, 0)); >> Maybe just pci_get_slot(pdev->bus, PCI_DEVFN(0, 0)) ? >> >> I guess if we want to be pedantic we could go for: >> >> bus = pci_find_host_bridge(pdev->bus)->bus; >> pci_get_slot(bus, PCI_DEVFN(0, 0)) >> >> but I think the GPU should always be on the root bus, so the simpler >> form should be fine. >> > > All three of these should be correct. > > I'll use pci_get_slot(pdev->bus, PCI_DEVFN(0, 0)) as you suggested. > Now that I think about this more, I think my version is a simpler change and does not introduce "new features" by assuming GPU and host to be on the same bus similar to the original code. Original code could have used pci_get_slot() too. Since all of them are correct, mine is slightly more correct; I'd like to keep mine. -- Sinan Kaya Qualcomm Datacenter Technologies, Inc. as an affiliate of Qualcomm Technologies, Inc. Qualcomm Technologies, Inc. is a member of the Code Aurora Forum, a Linux Foundation Collaborative Project. -- To unsubscribe from this list: send the line "unsubscribe linux-arm-msm" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html