Commit 413db06c05e7 ("phy: qcom-qmp-usb: clean up probe initialisation") removed most users of the platform device driver data from the qcom-qmp-usb driver, but mistakenly also removed the initialisation despite the data still being used in the runtime PM callbacks. This bug was later reproduced when the driver was copied to create the qmp-usbc driver. Restore the driver data initialisation at probe to avoid a NULL-pointer dereference on runtime suspend. Apparently no one uses runtime PM, which currently needs to be enabled manually through sysfs, with these drivers. Fixes: 19281571a4d5 ("phy: qcom: qmp-usb: split USB-C PHY driver") Cc: stable@xxxxxxxxxxxxxxx # 6.9 Signed-off-by: Johan Hovold <johan+linaro@xxxxxxxxxx> --- drivers/phy/qualcomm/phy-qcom-qmp-usbc.c | 1 + 1 file changed, 1 insertion(+) diff --git a/drivers/phy/qualcomm/phy-qcom-qmp-usbc.c b/drivers/phy/qualcomm/phy-qcom-qmp-usbc.c index 5cbc5fd529eb..dea3456f88b1 100644 --- a/drivers/phy/qualcomm/phy-qcom-qmp-usbc.c +++ b/drivers/phy/qualcomm/phy-qcom-qmp-usbc.c @@ -1049,6 +1049,7 @@ static int qmp_usbc_probe(struct platform_device *pdev) return -ENOMEM; qmp->dev = dev; + dev_set_drvdata(dev, qmp); qmp->orientation = TYPEC_ORIENTATION_NORMAL; -- 2.44.2