On Wed, 08 May 2024 22:34:14 +0200, Gabor Juhos wrote: > The clk_alpha_pll_stromer_plus_set_rate() function does not > sets the ALPHA_EN bit in the USER_CTL register, so setting > rates which requires using alpha mode works only if the bit > gets set already prior calling the function. > > Extend the function to set the ALPHA_EN bit in order to allow > using fractional rates regardless whether the bit gets set > previously or not. > > [...] Applied, thanks! [1/1] clk: qcom: clk-alpha-pll: set ALPHA_EN bit for Stromer Plus PLLs commit: 5a33a64524e6381c399e5e42571d9363ffc0bed4 Best regards, -- Bjorn Andersson <andersson@xxxxxxxxxx>