On Thu, 28 Mar 2024 08:54:31 +0100, Gabor Juhos wrote: > The clk_alpha_pll_stromer_set_rate() function writes inproper > values into the ALPHA_VAL{,_U} registers which results in wrong > clock rates when the alpha value is used. > > The broken behaviour can be seen on IPQ5018 for example, when > dynamic scaling sets the CPU frequency to 800000 KHz. In this > case the CPU cores are running only at 792031 KHz: > > [...] Applied, thanks! [1/1] clk: qcom: clk-alpha-pll: fix rate setting for Stromer PLLs commit: f837535fcb32a0313e07dd8ac49c2cfa43b49260 Best regards, -- Bjorn Andersson <andersson@xxxxxxxxxx>