Re: [PATCH] clk: qcom: clk-rcg2: Fix wrong RCG clock rate for high parent frequencies

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Quoting Devi Priya (2023-07-20 01:33:04)
> If the parent clock rate is greater than unsigned long max/2 then
> integer overflow happens when calculating the clock rate on 32-bit systems.
> As RCG2 uses half integer dividers, the clock rate is first being
> multiplied by 2 which will overflow the unsigned long max value. So, use
> unsigned long long for rate computations to avoid overflow.
> 
> Signed-off-by: Devi Priya <quic_devipriy@xxxxxxxxxxx>
> ---

Any Fixes tag?