[PATCH v2 04/15] thermal/drivers/db8500: remove redundant msg

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



The upper devm_request_threaded_irq() function prints directly
error message.

Signed-off-by: Yangtao Li <frank.li@xxxxxxxx>
---
 drivers/thermal/db8500_thermal.c | 8 ++------
 1 file changed, 2 insertions(+), 6 deletions(-)

diff --git a/drivers/thermal/db8500_thermal.c b/drivers/thermal/db8500_thermal.c
index fca5c2c93bf9..0a890d1338cf 100644
--- a/drivers/thermal/db8500_thermal.c
+++ b/drivers/thermal/db8500_thermal.c
@@ -167,10 +167,8 @@ static int db8500_thermal_probe(struct platform_device *pdev)
 	ret = devm_request_threaded_irq(dev, low_irq, NULL,
 		prcmu_low_irq_handler, IRQF_NO_SUSPEND | IRQF_ONESHOT,
 		"dbx500_temp_low", th);
-	if (ret < 0) {
-		dev_err(dev, "failed to allocate temp low irq\n");
+	if (ret < 0)
 		return ret;
-	}
 
 	high_irq = platform_get_irq_byname(pdev, "IRQ_HOTMON_HIGH");
 	if (high_irq < 0)
@@ -179,10 +177,8 @@ static int db8500_thermal_probe(struct platform_device *pdev)
 	ret = devm_request_threaded_irq(dev, high_irq, NULL,
 		prcmu_high_irq_handler, IRQF_NO_SUSPEND | IRQF_ONESHOT,
 		"dbx500_temp_high", th);
-	if (ret < 0) {
-		dev_err(dev, "failed to allocate temp high irq\n");
+	if (ret < 0)
 		return ret;
-	}
 
 	/* register of thermal sensor and get info from DT */
 	th->tz = devm_thermal_of_zone_register(dev, 0, th, &thdev_ops);
-- 
2.39.0