Hi, On Sat, Jul 25, 2015 at 06:04:14PM -0700, Bjorn Andersson wrote: > On Sat 25 Jul 08:42 PDT 2015, Sebastian Reichel wrote: > > * battery-charge-control-limit > > > > It's unclear, what this property is used for. Is the limit only > > for "normal" charging or also for fast charging? > > > > This is described as the current limit during fast charging. However, > "fast charging" is the normal state. > > I think the most consistent (regards documentation and other properties) > would be: > > qcom,fast-charge-current-limit So what's the difference to "fast-charge-safe-current"? > > * minimum-input-voltage > > > > Add a vendor prefix to this property. > > > > Shouldn't they all have a vendor prefix? Some of the properties are quite generic and used on multiple chips, so we may create a power_supply/battery-fuel-gauge.txt and power_supply/battery-charger.txt with generic bindings. I'm fine with just adding vendor prefixed properties for all instances, though. > Thanks for the review, I'll update the patches accordingly and > will send out v2 (and make sure you get the dt binding document > as well). OK, thanks. -- Sebastian