On 23/11/2022 12:19, Krzysztof Kozlowski wrote:
On 23/11/2022 00:12, Dmitry Baryshkov wrote:
Mark clock-names property as required to be used on all MDSS devices.
This we see from the diff. Please tell why you are doing it. In some
other recent bindings we dropped clock-names from required, so this is
confusing.
Thanks for the question. It looks like you are correct and we do not
need clock-names for the new mdss devices (only for the DPU devices and
for the old qcom,mdss binding, but it's another story).
So, I'll drop this patch from the series. And for the next cycle I will
check whether we can drop the clock-names from existing dtsi files (and
from schema too).
--
With best wishes
Dmitry