The source clock for the reference clock should not be described by the devicetree and instead this relationship should be modelled in the clock driver. Drop the management of the source clock from the driver for SC8180X and SC8280XP. Note that support for the former is not yet in mainline. Also note that the binding has never been updated to describe the v4 clocks for SC8180X. Signed-off-by: Johan Hovold <johan+linaro@xxxxxxxxxx> --- drivers/phy/qualcomm/phy-qcom-qmp-combo.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/phy/qualcomm/phy-qcom-qmp-combo.c b/drivers/phy/qualcomm/phy-qcom-qmp-combo.c index c5d8f8bfaaaa..5da42a4e5bf6 100644 --- a/drivers/phy/qualcomm/phy-qcom-qmp-combo.c +++ b/drivers/phy/qualcomm/phy-qcom-qmp-combo.c @@ -945,7 +945,7 @@ static const char * const qmp_v3_phy_clk_l[] = { }; static const char * const qmp_v4_phy_clk_l[] = { - "aux", "ref_clk_src", "ref", "com_aux", + "aux", "ref", "com_aux", }; /* the primary usb3 phy on sm8250 doesn't have a ref clock */ -- 2.37.4