Re: [PATCH v3 09/12] drm/msm/dp: HPD handling relates to next_bridge

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 




On 26 October 2022 06:26:21 EEST, Bjorn Andersson <quic_bjorande@xxxxxxxxxxx> wrote:
>From: Bjorn Andersson <bjorn.andersson@xxxxxxxxxx>
>
>The DisplayPort controller's internal HPD interrupt handling is used for
>cases where the HPD signal is connected to a GPIO which is pinmuxed into
>the DisplayPort controller.
>
>Most of the logic for enabling and disabling the HPD-related interrupts
>is conditioned on the presence of an EDP panel, but more generically
>designs that has a downstream drm_bridge (next_bridge) could use this to
>handle the HPD interrupts, instead of the internal mechanism.
>
>So replace the current is_edp-based guards with a check for the presence
>of next_bridge.

This does not sound correct. The next bridge might be a dummy bridge, not supporting the hpd. Please change this to use the enable_hpd()/disable_hpd() callbacks. This way the drm_bridge_connector framework will make sure to enable hpd handling for the bridge that is actually supposed to generate hpd events.


>
>Signed-off-by: Bjorn Andersson <bjorn.andersson@xxxxxxxxxx>
>Signed-off-by: Bjorn Andersson <quic_bjorande@xxxxxxxxxxx>
>---
>
>Changes since v2:
>- None


-- 
With best wishes