On 27/06/2022 22:10, Bjorn Andersson wrote: > On Mon 27 Jun 04:32 CDT 2022, Krzysztof Kozlowski wrote: > >> DT schema expects names of operating points tables to start with >> "opp-table": >> >> ipq6018-cp01-c1.dtb: cpu_opp_table: $nodename:0: 'cpu_opp_table' does not match '^opp-table(-[a-z0-9]+)?$' >> >> Use hyphens instead of underscores, fix the names to match DT schema or >> remove the prefix entirely when it is not needed. >> >> Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx> > > Reviewed-by: Bjorn Andersson <bjorn.andersson@xxxxxxxxxx> Hi Bjorn, I was expecting you to take it... Does your review means I should push it independently? I can do this, but it is not the preferred way as it increases chances of conflicts. I am taking only cleanup stuff, usually mine, which other maintainers miss. Best regards, Krzysztof