On Wed, 18 May 2022 13:35:54 +0300, Vladimir Zapolskiy wrote: > Access to I/O of SM8250 camera clock controller IP depends on enabled > GCC_CAMERA_AHB_CLK clock supplied by global clock controller, the latter > one is inited on subsys level, so, to satisfy the dependency, it would > make sense to deprive the init level of camcc-sm8250 driver. > > If both drivers are compiled as built-in, there is a change that a board > won't boot up due to a race, which happens on the same init level. > > [...] Applied, thanks! [1/1] clk: qcom: camcc-sm8250: Fix halt on boot by reducing driver's init level commit: c4f40351901a10cd662ac2c081396d8fb04f584d Best regards, -- Bjorn Andersson <bjorn.andersson@xxxxxxxxxx>