On 1.05.2022 22:20, Konrad Dybcio wrote: > MSM8994, despite being heavily based on MSM8974, uses the > 1.2 version of TSENS. Also, 8994 being 8994, it has a custom > way of calculating the slope. > > MSM8992 in turn is a cut-down version of MSM8994 and uses > the same TSENS hardware, albeit with a different set of sensors. > > Also tested on 8976 (by a person who didn't want to be named) > to make sure the 11->16 max_sensors changes didn't break anything. > > Signed-off-by: Konrad Dybcio <konrad.dybcio@xxxxxxxxxxxxxx> > --- Bumping this, as it's seemingly went unseen. Konrad