On 26/06/2022 05:28, Bjorn Andersson wrote: > On Thu 23 Jun 07:58 CDT 2022, Krzysztof Kozlowski wrote: > >> On 23/06/2022 08:48, Rajendra Nayak wrote: >>>>>> diff --git a/arch/arm64/boot/dts/qcom/sdm845.dtsi b/arch/arm64/boot/dts/qcom/sdm845.dtsi >>>>>> index 83e8b63f0910..adffb9c70566 100644 >>>>>> --- a/arch/arm64/boot/dts/qcom/sdm845.dtsi >>>>>> +++ b/arch/arm64/boot/dts/qcom/sdm845.dtsi >>>>>> @@ -2026,6 +2026,60 @@ llcc: system-cache-controller@1100000 { >>>>>> interrupts = <GIC_SPI 582 IRQ_TYPE_LEVEL_HIGH>; >>>>>> }; >>>>>> >>>>>> + pmu@1436400 { >>>>>> + compatible = "qcom,sdm845-cpu-bwmon"; >>>>>> + reg = <0 0x01436400 0 0x600>; >>>>>> + >>>>>> + interrupts = <GIC_SPI 581 IRQ_TYPE_LEVEL_HIGH>; >>>>>> + >>>>>> + interconnects = <&gladiator_noc MASTER_APPSS_PROC 3 &mem_noc SLAVE_EBI1 3>, >>>>>> + <&osm_l3 MASTER_OSM_L3_APPS &osm_l3 SLAVE_OSM_L3>; >>>>>> + interconnect-names = "ddr", "l3c"; >>>>> >>>>> Is this the pmu/bwmon instance between the cpu and caches or the one between the caches and DDR? >>>> >>>> To my understanding this is the one between CPU and caches. >>> >>> Ok, but then because the OPP table lists the DDR bw first and Cache bw second, isn't the driver >>> ending up comparing the bw values thrown by the pmu against the DDR bw instead of the Cache BW? >> >> I double checked now and you're right. >> >>> Atleast with my testing on sc7280 I found this to mess things up and I always was ending up at >>> higher OPPs even while the system was completely idle. Comparing the values against the Cache bw >>> fixed it.(sc7280 also has a bwmon4 instance between the cpu and caches and a bwmon5 between the cache >>> and DDR) >> >> In my case it exposes different issue - under performance. Somehow the >> bwmon does not report bandwidth high enough to vote for high bandwidth. >> >> After removing the DDR interconnect and bandwidth OPP values I have for: >> sysbench --threads=8 --time=60 --memory-total-size=20T --test=memory >> --memory-block-size=4M run >> >> 1. Vanilla: 29768 MB/s >> 2. Vanilla without CPU votes: 8728 MB/s >> 3. Previous bwmon (voting too high): 32007 MB/s >> 4. Fixed bwmon 24911 MB/s >> Bwmon does not vote for maximum L3 speed: >> bwmon report 9408 MB/s (thresholds set: <9216000 15052801> >> ) >> osm l3 aggregate 14355 MBps -> 897 MHz, level 7, bw 14355 MBps >> >> Maybe that's just problem with missing governor which would vote for >> bandwidth rounding up or anticipating higher needs. >> >>>>> Depending on which one it is, shouldn;t we just be scaling either one and not both the interconnect paths? >>>> >>>> The interconnects are the same as ones used for CPU nodes, therefore if >>>> we want to scale both when scaling CPU, then we also want to scale both >>>> when seeing traffic between CPU and cache. >>> >>> Well, they were both associated with the CPU node because with no other input to decide on _when_ >>> to scale the caches and DDR, we just put a mapping table which simply mapped a CPU freq to a L3 _and_ >>> DDR freq. So with just one input (CPU freq) we decided on what should be both the L3 freq and DDR freq. >>> >>> Now with 2 pmu's, we have 2 inputs, so we can individually scale the L3 based on the cache PMU >>> counters and DDR based on the DDR PMU counters, no? >>> >>> Since you said you have plans to add the other pmu support as well (bwmon5 between the cache and DDR) >>> how else would you have the OPP table associated with that pmu instance? Would you again have both the >>> L3 and DDR scale based on the inputs from that bwmon too? >> >> Good point, thanks for sharing. I think you're right. I'll keep only the >> l3c interconnect path. >> > > If I understand correctly, <&osm_l3 MASTER_OSM_L3_APPS &osm_l3 > SLAVE_OSM_L3> relates to the L3 cache speed, which sits inside the CPU > subsystem. As such traffic hitting this cache will not show up in either > bwmon instance. > > The path <&gladiator_noc MASTER_APPSS_PROC 3 &mem_noc SLAVE_EBI1 3> > affects the DDR frequency. So the traffic measured by the cpu-bwmon > would be the CPU subsystems traffic that missed the L1/L2/L3 caches and > hits the memory bus towards DDR. > > > If this is the case it seems to make sense to keep the L3 scaling in the > opp-tables for the CPU and make bwmon only scale the DDR path. What do > you think? The reported data throughput by this bwmon instance is beyond the DDR OPP table bandwidth, e.g.: 16-22 GB/s, so it seems it measures still within cache controller, not the memory bus. Best regards, Krzysztof