Quoting Dmitry Baryshkov (2022-06-17 05:29:21) > Convert the clock driver to specify parent data rather than parent > names, to actually bind using 'clock-names' specified in the DTS rather > than global clock names. Use parent_hws where possible to refer parent > clocks directly, skipping the lookup. > > Signed-off-by: Dmitry Baryshkov <dmitry.baryshkov@xxxxxxxxxx> > --- Any reason to not move directly to DT index numbers instead of string names? Anyway, Reviewed-by: Stephen Boyd <sboyd@xxxxxxxxxx>