Re: [PATCH v6 1/5] drm/msm/disp/dpu1: set mdp clk to the maximum frequency in opp table during probe

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Quoting Vinod Polimera (2022-03-14 07:46:53)
> use max clock during probe/bind sequence from the opp table.
> The clock will be scaled down when framework sends an update.

Capitalize 'use'.

Why is it important to use max frequency during probe/bind? Does not
setting the clk rate during probe mean that we'll never use the max
rate? Does it speed things up during probe?