Quoting Dmitry Baryshkov (2021-12-15 11:36:58) > Convert the clock driver to specify parent hws/data rather than parent > names, to actually bind using 'clock-names' specified in the DTS rather > than global clock names. > > Signed-off-by: Dmitry Baryshkov <dmitry.baryshkov@xxxxxxxxxx> > Reviewed-by: Marijn Suijten <marijn.suijten@xxxxxxxxxxxxxx> > --- Reviewed-by: Stephen Boyd <sboyd@xxxxxxxxxx>