Re: [PATCH] ACPI / battery: Fix reporting "Not charging" when capacity is 100%

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi,

On 03-11-18 07:57, João Paulo Rechi Vita wrote:
Commit 19fffc8450d4378580a8f019b195c4617083176f fixed reporting
"Discharging" on some machines when AC was connected but the battery was
not charging. But now on these machines the battery status is reported
as "Not charging" even when the battery is fully charged.

This commit takes the battery capacity into consideration when checking
if "Not charging" should be returned and "Full" is returned when the
capacity is 100%.

Signed-off-by: João Paulo Rechi Vita <jprvita@xxxxxxxxxxxx>

acpi_battery_handle_discharging() only gets called if the ACPI_BATTERY_STATE_DISCHARGING
bit is set by the firmware in that case if we are not actually discharging
returning POWER_SUPPLY_STATUS_NOT_CHARGING is the only correct thing to do,
we should never return POWER_SUPPLY_STATUS_FULL when the
ACPI_BATTERY_STATE_DISCHARGING bit is set.

I was about to point you to the upower bug for upower not
handling POWER_SUPPLY_STATUS_NOT_CHARGING as well as it
could atm, but I see you've already found that and are working
on fixing that. That is great, thank you.

As for this kernel-side fix I do not believe that fixing thus in
the kernel is the right thing to do. We try to stay away from
heuristics using full_charge_capacity in the kernel since that
is not really reliable / deterministic.

Regards,

Hans




---
  drivers/acpi/battery.c | 6 +++++-
  1 file changed, 5 insertions(+), 1 deletion(-)

diff --git a/drivers/acpi/battery.c b/drivers/acpi/battery.c
index cb97b6105f52..82e194290f01 100644
--- a/drivers/acpi/battery.c
+++ b/drivers/acpi/battery.c
@@ -217,8 +217,12 @@ static int acpi_battery_handle_discharging(struct acpi_battery *battery)
  	 * was plugged in and the device thus did not start a new charge cycle.
  	 */
  	if ((battery_ac_is_broken || power_supply_is_system_supplied()) &&
-	    battery->rate_now == 0)
+	    battery->rate_now == 0) {
+		if (battery->capacity_now && battery->full_charge_capacity &&
+		    battery->capacity_now / battery->full_charge_capacity == 1)
+			return POWER_SUPPLY_STATUS_FULL;
  		return POWER_SUPPLY_STATUS_NOT_CHARGING;
+	}
return POWER_SUPPLY_STATUS_DISCHARGING;
  }




[Index of Archives]     [Linux IBM ACPI]     [Linux Power Management]     [Linux Kernel]     [Linux Laptop]     [Kernel Newbies]     [Share Photos]     [Security]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Samba]     [Video 4 Linux]     [Device Mapper]     [Linux Resources]