Replace direct calls to power supply function attributes with wrappers. Wrappers provide safe access in case of unregistering the power supply (e.g. by removing the driver). Replace: - get_property -> power_supply_get_property Signed-off-by: Krzysztof Kozlowski <k.kozlowski@xxxxxxxxxxx> Acked-by: Jonghwa Lee <jonghwa3.lee@xxxxxxxxxxx> Acked-by: Pavel Machek <pavel@xxxxxx> Reviewed-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@xxxxxxxxxxx> Reviewed-by: Sebastian Reichel <sre@xxxxxxxxxx> --- drivers/power/charger-manager.c | 37 ++++++++++++++++++++----------------- 1 file changed, 20 insertions(+), 17 deletions(-) diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c index df27600880b9..a5b86b60d244 100644 --- a/drivers/power/charger-manager.c +++ b/drivers/power/charger-manager.c @@ -103,8 +103,8 @@ static bool is_batt_present(struct charger_manager *cm) if (!psy) break; - ret = psy->get_property(psy, - POWER_SUPPLY_PROP_PRESENT, &val); + ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_PRESENT, + &val); if (ret == 0 && val.intval) present = true; break; @@ -118,8 +118,8 @@ static bool is_batt_present(struct charger_manager *cm) continue; } - ret = psy->get_property(psy, POWER_SUPPLY_PROP_PRESENT, - &val); + ret = power_supply_get_property(psy, + POWER_SUPPLY_PROP_PRESENT, &val); if (ret == 0 && val.intval) { present = true; break; @@ -155,7 +155,8 @@ static bool is_ext_pwr_online(struct charger_manager *cm) continue; } - ret = psy->get_property(psy, POWER_SUPPLY_PROP_ONLINE, &val); + ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_ONLINE, + &val); if (ret == 0 && val.intval) { online = true; break; @@ -183,7 +184,7 @@ static int get_batt_uV(struct charger_manager *cm, int *uV) if (!fuel_gauge) return -ENODEV; - ret = fuel_gauge->get_property(fuel_gauge, + ret = power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_VOLTAGE_NOW, &val); if (ret) return ret; @@ -223,7 +224,8 @@ static bool is_charging(struct charger_manager *cm) } /* 2. The charger should be online (ext-power) */ - ret = psy->get_property(psy, POWER_SUPPLY_PROP_ONLINE, &val); + ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_ONLINE, + &val); if (ret) { dev_warn(cm->dev, "Cannot read ONLINE value from %s\n", cm->desc->psy_charger_stat[i]); @@ -236,7 +238,8 @@ static bool is_charging(struct charger_manager *cm) * 3. The charger should not be FULL, DISCHARGING, * or NOT_CHARGING. */ - ret = psy->get_property(psy, POWER_SUPPLY_PROP_STATUS, &val); + ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_STATUS, + &val); if (ret) { dev_warn(cm->dev, "Cannot read STATUS value from %s\n", cm->desc->psy_charger_stat[i]); @@ -279,7 +282,7 @@ static bool is_full_charged(struct charger_manager *cm) val.intval = 0; /* Not full if capacity of fuel gauge isn't full */ - ret = fuel_gauge->get_property(fuel_gauge, + ret = power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_CHARGE_FULL, &val); if (!ret && val.intval > desc->fullbatt_full_capacity) return true; @@ -296,7 +299,7 @@ static bool is_full_charged(struct charger_manager *cm) if (desc->fullbatt_soc > 0) { val.intval = 0; - ret = fuel_gauge->get_property(fuel_gauge, + ret = power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_CAPACITY, &val); if (!ret && val.intval >= desc->fullbatt_soc) return true; @@ -580,7 +583,7 @@ static int cm_get_battery_temperature_by_psy(struct charger_manager *cm, if (!fuel_gauge) return -ENODEV; - return fuel_gauge->get_property(fuel_gauge, + return power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_TEMP, (union power_supply_propval *)temp); } @@ -900,7 +903,7 @@ static int charger_get_property(struct power_supply *psy, ret = -ENODEV; break; } - ret = fuel_gauge->get_property(fuel_gauge, + ret = power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_CURRENT_NOW, val); break; case POWER_SUPPLY_PROP_TEMP: @@ -919,7 +922,7 @@ static int charger_get_property(struct power_supply *psy, break; } - ret = fuel_gauge->get_property(fuel_gauge, + ret = power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_CAPACITY, val); if (ret) break; @@ -975,7 +978,7 @@ static int charger_get_property(struct power_supply *psy, break; } - ret = fuel_gauge->get_property(fuel_gauge, + ret = power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_CHARGE_NOW, val); if (ret) { @@ -1424,7 +1427,7 @@ static int cm_init_thermal_data(struct charger_manager *cm, int ret; /* Verify whether fuel gauge provides battery temperature */ - ret = fuel_gauge->get_property(fuel_gauge, + ret = power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_TEMP, &val); if (!ret) { @@ -1718,13 +1721,13 @@ static int charger_manager_probe(struct platform_device *pdev) cm->charger_psy.num_properties = psy_default.num_properties; /* Find which optional psy-properties are available */ - if (!fuel_gauge->get_property(fuel_gauge, + if (!power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_CHARGE_NOW, &val)) { cm->charger_psy.properties[cm->charger_psy.num_properties] = POWER_SUPPLY_PROP_CHARGE_NOW; cm->charger_psy.num_properties++; } - if (!fuel_gauge->get_property(fuel_gauge, + if (!power_supply_get_property(fuel_gauge, POWER_SUPPLY_PROP_CURRENT_NOW, &val)) { cm->charger_psy.properties[cm->charger_psy.num_properties] = -- 1.9.1 -- To unsubscribe from this list: send the line "unsubscribe linux-acpi" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html