Re: SPCR table parsing

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Fri, Jan 16, 2015 at 03:08:37AM +0000, Jon Masters wrote:
> Hi Folks,
> 
> We're implementing support for SPCR table parsing shortly[0], since it
> will allow to deprecate supplying a "console=" (and eventually, also
> "earlycon=") on 64-bit ARM servers, where it's not always the case that
> we can assume a 16550 at a specific address. SPCR has been provided on
> x86 systems since 2000 but is not (yet) supported by Linux.

For anyone using DT rather than ACPI, the same can be achieved in
mainline with /chosen/stdout-path as of:

7914a7c5651a5161 "of: support passing console options with stdout-path"

Documented in:

2a9d832cc9aae21e "of: Add bindings for chosen node, stdout-path"

e.g.

uart: serial@f00 {
	reg = <0xf00 0x200>;
	compatible = "vendor,some-serial-device";
};

chosen {
	stdout-path = "/serial@f00:115200n8";
};

This will be used for both the console and earlycon. Please make use of
this where possible.

Thanks,
Mark.
--
To unsubscribe from this list: send the line "unsubscribe linux-acpi" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html



[Index of Archives]     [Linux IBM ACPI]     [Linux Power Management]     [Linux Kernel]     [Linux Laptop]     [Kernel Newbies]     [Share Photos]     [Security]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Samba]     [Video 4 Linux]     [Device Mapper]     [Linux Resources]